56-U04-E01 Spectrum Control, 56-U04-E01 Datasheet - Page 18

USB CONNECTOR, RECEPTACLE, 4POS, THD

56-U04-E01

Manufacturer Part Number
56-U04-E01
Description
USB CONNECTOR, RECEPTACLE, 4POS, THD
Manufacturer
Spectrum Control
Series
USB-Er
Datasheet

Specifications of 56-U04-E01

Connector Type
USB
No. Of Contacts
4
Contact Termination
Right Angle Through Hole
Connector Mounting
PCB
Gender
Receptacle
Contact Plating
Gold
Product
USB Type A Connectors
Standard
USB
Number Of Ports
1
Features
Spectrum USB Filtered Connectors TYPE A R/A USB .05pF 5A 10VDC
Insulation Resistance
10 MOhms
Mounting Angle
Right
Number Of Positions / Contacts
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
18
EMI/RFI Filter and Capacitor
Performance Testing
Reliability Levels
Class B
Class B is outlined in MIL-F-28861 and is prescribed for
most military/aerospace requirements. It is more stringent
than MIL-F-15733 requiring 100% screening that includes
thermal shock, voltage conditioning and x-ray.
Periodic Group B testing is performed on units selected
at random from production lots.
Class B Test Sequence Summary
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
AC voltage drop (when applicable)
Voltage and temperature limits of capacitance
Insertion loss (at temperature)
Barometric pressure (reduced)
Temperature rise
Current overload
Terminal strength
Thermal shock and immersion
Life
Resistance to soldering heat
Salt spray (corrosion)
Radiographic inspection
Resistance to solvents
Shock (specified pulse)
Vibration (high frequency)
Moisture resistance
Seal (when applicable)
Radiographic inspection
Subgroup 1
Subgroup 2
Subgroup 3
Inspection
Group III
Group II
Group I
Class
B
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
“R” level testing
“R” level screening is performed by Spectrum Control’s
Hi-Rel Laboratory as detailed below. Customers requiring
special tests may order to their own specifications or sim-
ply order to level R and then note additions or deviations.
“R” level test sequence
(100% testing unless otherwise specified)
s
s
s
s
s
s
s
s
s
s
Thermal Shock: 5 cycles from -55°C to +125°C in
Visual and Mechanical: in accordance with MIL-F-15733.
accordance with MIL-STD-202, Method 107D,
Condition A.
Burn-in: 100 hours at 1.4x rated DC voltage, 125°C.
Seal Test: MIL-STD-202, Method 112, Test Condition A.
Hermetic seal parts only.
Capacitance and Dissipation Factor: MIL-STD-202,
Method 305, frequency 1kHz.
Dielectric Withstanding Voltage: 2.5 times the rated DC
voltage for 5 ± 1 second at 25°C, with 50 mA maximum
charging current.
Insulation Resistance: MIL-STD-202, Method 302,
125°C at rated DC voltage and room temperature
(25°C). The 125°C requirement shall be 10% of the
specified catalog IR at 25°C.
DC Resistance: MIL-STD-202, Method 303.
Insertion Loss Test — Sample per MIL-F-15733.
At full rated load in accordance with MIL-STD-220.
The minimum insertion loss shall be defined in the
filter catalog.
Marking: All filters which have successfully completed
the test sequence shall be marked with an “R” in the
second part of the number. For example, a standard
SCI-2130-004 becomes SCI-R2130-004 and 9051-100-
0000 becomes 9051-R100-0000, and 51-719-011
becomes 51-R719-011 after completion of the Hi-Rel
Level “R” Test Sequence.