56-U04-E01 Spectrum Control, 56-U04-E01 Datasheet - Page 6

USB CONNECTOR, RECEPTACLE, 4POS, THD

56-U04-E01

Manufacturer Part Number
56-U04-E01
Description
USB CONNECTOR, RECEPTACLE, 4POS, THD
Manufacturer
Spectrum Control
Series
USB-Er
Datasheet

Specifications of 56-U04-E01

Connector Type
USB
No. Of Contacts
4
Contact Termination
Right Angle Through Hole
Connector Mounting
PCB
Gender
Receptacle
Contact Plating
Gold
Product
USB Type A Connectors
Standard
USB
Number Of Ports
1
Features
Spectrum USB Filtered Connectors TYPE A R/A USB .05pF 5A 10VDC
Insulation Resistance
10 MOhms
Mounting Angle
Right
Number Of Positions / Contacts
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
6
Applications
Features/
Benefits
Performance
Characteristics
EMI Filters and Filtered Interconnects
Selection Guide
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Telecommunications equipment,
cellular base stations, linear power
amplifiers, cellular microcell repeaters,
industrial, scientific, remote sensory,
and medical equipment
s Total reduced costs –
s Excellent filtering –
s Reliability –
s Standard centers –
s Easy Mate™ filter plate –
s Insertion loss range –
s Capacitance –
s Temperature characteristics –
s Temperature range –
s Voltage ratings (max.) –
s Current ratings (max.) –
www.spectrumcontrol.com/array
Economical method of meeting
EMC requirements
Outperform surface mount
filters at frequencies above
130 MHz; provide an EMI
filtered signal line between
electronic system modules
Every filter plate is tested 100%
for key parameters
Of 0.100" and 2mm allow
for easy termination
Design provides for quick
installation into predefined cutout
Effective insertion loss from
1 MHz to 18 GHz with
proper installation
Pi: 68 pF to 5000 pF
Feed-thru: 68 pF to 4000 pF
NPO, X7R, Z5U
-55°C to +125°C
To 250 VDC
To 5 Amps standard
Assemblies
Filter Plate
Pages 105-115
Telecommunications equipment,
cellular base stations, linear power
amplifiers, cellular microcell repeaters,
industrial, scientific, remote sensory,
and medical equipment
s Design flexibility –
s Standard centers –
s Reliability –
s Excellent filtering –
s Rugged construction –
s Insertion loss range –
s Capacitance –
s Temperature characteristics –
s Temperature range –
s Voltage ratings (max.) –
s Current ratings (max.) –
www.spectrumcontrol.com/array
Available in 10 to 64 positions
Mates to most ribbon
cable connectors
A variety of latch ejector
heights available
Mixed capacitance values
and schematics available
Pins on .100" centers
Cable retention reliable in
vibration prone environments
From 5 MHz to 1 GHz
and beyond
Shroud protects filter element
from potential damage
Effective insertion loss from
1 MHz to 18 GHz with
proper installation
Pi: 68 pF to 5000 pF
Feed-thru: 68 pF to 4000 pF
NPO, X7R, Z5U
-55°C to +125°C
To 250 VDC
To 5 Amps standard
Latch Plates
Shrouded
FILTERED ARRAYS
Pages 116-117
www.spectrumcontrol.com/mcpck
Telecommunications equipment,
scientific equipment, aerospace
applications and point-to-point
telemetry
s Total reduced costs –
s Design flexibility –
s Hermetically sealed –
s Insertion loss range –
s Temperature range –
s Voltage ratings (max.) –
s Current ratings (max.) –
Allow users to reduce
production and installation time
while lowering overall costs
Wide variety of shapes and sizes
Housing materials include:
Kovar, Aluminum, Copper,
Titanium and Copper Alloys
Variety of circuits: C, L and Pi
Connectors offered are: RF,
SMA, Bias Pins and Snap-ins
Available in both hermetic and
non-hermetic packaging
From 1 MHz to 18 GHz
-55°C to +125°C
To 200 VDC
To 5 Amps
Microcircuit
Packages
Pages 118-121
Telecommunications equipment,
industrial controls, power supplies,
uninterruptible power supplies,
instrumentation and power
distribution equipment
s Rugged construction –
s Design flexibility –
s Performance –
s Reliability – Every terminal block
s European style blocks –
s FED/MIL approvals –
s Insertion loss range –
s Capacitance –
s Temperature range –
s Voltage ratings (max.) –
s Current ratings (max.) –
www.spectrumcontrol.com/array
Provides protection to filtering
element; especially useful for
repeated changes in field wiring
2 to 6 terminals available
in either the “Barrier Strip”
or European variety
Filter elements provide high
insertion loss for EMI filtering
of DC power and control lines
is tested 100% for key parameters
Available in English and
metric spacing
Barrier strips are recognized
to U.L. 1059 file E133076
and approved by CSA Std
22.2 No. 158-1987 and
ECN584B, LR92537;
52-160 series 100 VDC UL/CSA
52-257 series 250 VAC UL/CSA
Effective insertion loss
from 1 MHz to 18 GHz
with proper installation
2500 pF to 5200 pF
-55°C to +105°C
Barrier: to 250 VAC
European: to 100 VDC
Barrier: 20 Amps
European: 12 Amps
Terminal Blocks
Filtered
Pages 122-127

Related parts for 56-U04-E01