PSB21373HV1.1XT Infineon Technologies, PSB21373HV1.1XT Datasheet - Page 118

no-image

PSB21373HV1.1XT

Manufacturer Part Number
PSB21373HV1.1XT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of PSB21373HV1.1XT

Lead Free Status / RoHS Status
Compliant
(center frequency, bandwidth and attenuation of the stop-band) are programmable by
the CRAM parameters listed in Table Chapter 16
Table 16 CRAM Parameters of the Tone Filter
Parameter
A1
A2
K
GE
A maximum attenuation of the first harmonic frequency of 50 dB is possible. Figure
Chapter 62 shall illustrate the equalizer parameters.
Figure 62
Filter Parameters of the Equalizer
The two main purposes of the programmable saturation amplification are:
• Level balancing of the filtered signal (avoidance of overload effects).
• Amplification up to + 12 dB followed by a saturation (3.14 dBm0) of the incoming
Data Sheet
signal. This saturation amplification converts a sine-wave signal into a square-wave
# of CRAM
Bytes
1
1
1
1
Range
200 Hz to 4 kHz
0 to – 1
0 to 54 dB
+ 12 to – 12 dB
118
Comment
Center frequency
Determines with A1 and K the
bandwidth. The closer A2 comes
to -1, the smaller the bandwidth.
Attenuation of the stop-band
Saturation amplification
PSB 21373
2002-05-13

Related parts for PSB21373HV1.1XT