KSZ8842-16MQL Micrel Inc, KSZ8842-16MQL Datasheet - Page 93

IC SWITCH 10/100 16BIT 128PQFP

KSZ8842-16MQL

Manufacturer Part Number
KSZ8842-16MQL
Description
IC SWITCH 10/100 16BIT 128PQFP
Manufacturer
Micrel Inc
Datasheets

Specifications of KSZ8842-16MQL

Data Rate
100Mbps
Controller Type
Ethernet Switch Controller
Interface
PCI
Voltage - Supply
3.1 V ~ 3.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
128-MQFP, 128-PQFP
No. Of Ports
1
Ethernet Type
IEEE 802.3u
Supply Current
122mA
Supply Voltage Range
3.1V To 3.5V
Operating Temperature Range
0°C To +70°C
Digital Ic Case Style
QFP
No. Of
RoHS Compliant
Number Of Primary Switch Ports
2
Internal Memory Buffer Size
32
Operating Supply Voltage (typ)
3.3V
Fiber Support
Yes
Integrated Led Drivers
Yes
Phy/transceiver Interface
MII
Power Supply Type
Analog/Digital
Package Type
PQFP
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Pin Count
128
Mounting
Surface Mount
Jtag Support
No
Operating Supply Voltage (max)
3.5V
Operating Supply Voltage (min)
3.1V
Operating Temperature Classification
Commercial
Interface Type
PCI
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
576-1634 - BOARD EVALUATION KSZ8842-16MQL
Current - Supply
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
576-1478-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8842-16MQL
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8842-16MQLI
Manufacturer:
MICREL
Quantity:
760
Bank 49 Port 1 PHY Special Control/Status, LinkMD (0x00): P1SCSLMD
Bit
15
14-13
12
11
10
9
8-0
Micrel Confidential
November 2005
Default
0
0x0
0
0
1
0
0x000
R/W
RO
RO
RW
SC
RW
RW
RW
RO
Description
Vct_10m_short
1 = Less than 10 meter short.
Vct_result
VCT result.
[00] = normal condition.
[01] = open condition has been detected in
cable.
[10] = short condition has been detected in
cable.
[11] = cable diagnostic test is failed.
Vct_en
Vct enable.
1 = the cable diagnostic test is enabled. It
is self-cleared after the VCT test is done.
0 = it indicates the cable diagnostic test is
completed and the status information is
valid for read.
Force_lnk
Force link.
1 = force link pass.
0 = normal operation.
pwrsave
Power-saving.
1 = disable power saving.
0 = enable power saving.
Remote (Near-End) Loopback (rlb)
1 = perform remote loopback at Port 1's
PHY (RXP1/RXM1 -> TXP1/TXM1, see
Figure 15)
0 = normal operation
Vct_fault_count
VCT fault count.
Distance to the fault. It’s approximately
0.4m*vct_fault_count.
93
Bit is same as:
Bank 47 0x00 bit 12
Bank 47 0x00 bit 14-13
Bank 47 0x00 bit 15
Bank 47 0x02 bit 3
Bank 47 0x02 bit 2
Bank 47 0x02 bit 1
Bank 47 0x00 bit 8-0
KSZ8842-16/32 MQL/MVL
Rev. 1.4

Related parts for KSZ8842-16MQL