XW2Z-200J-B10 Omron, XW2Z-200J-B10 Datasheet - Page 244

no-image

XW2Z-200J-B10

Manufacturer Part Number
XW2Z-200J-B10
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B10

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB10
Analog Input Functions
A570
A571
A572
A573
A574
A575
Word
00
01
02
03
04 to 06
07
08 to 11
12
13
14
15
00
01 to 14
15
00 to 15
00 to 15
00 to 15
00 to 15
Bits
Adjustment
Mode Com-
mand Bits
(Effective only
when A575 is
5A5A hex.)
Adjustment
Mode Status
Adjustment
Mode Monitor
(Effective only
when A575 is
5A5A hex.)
Adjustment Mode Password
Function
Adjustment
Enable
Reserved
Adjustment Mode
Specifier
Reserved
Adjustment Value
Increment
Adjustment Value
Decrement
Adjustment Value
Clear
Adjustment Value
Set
Adjustment Oper-
ation Error
Reserved
Adjustment Mode
Started
Used for Analog
Input and Analog
Outputs 1/2
Analog Inputs
Analog Input
Reserved
Analog Output 1
Analog Output 2
OFF: Offset adjustment
ON:
While this bit is ON, the offset or gain value will be
incremented by one resolution unit each 0.5 s.
While this bit is ON, the offset or gain value will be
decremented by one resolution unit each 0.5 s.
OFF to ON: Clears the adjustment data to the fac-
OFF to ON: Reads the present value in the
ON when an operational error has been made,
such as turning ON both the Analog Input and Ana-
log Output 2 Adjustment Enable Bits at the same
time.
ON during adjustment mode operation (when A575
contains 5A5A hex).
Setting Offset Moni-
tor
Gain Value Monitor
Number of Average
Value Samples in
Adjustment Mode
5A5A hex: Adjustment mode enabled.
Other value: Adjustment mode disabled.
Gain adjustment
tory defaults.
Adjustment Value Monitor Area (A572
and A573) and saves this value to
flash memory. This adjustment value
will be used for the next normal mode
operation.
Settings
OFF: Adjustment disabled.
ON:
When this bit is turned from
OFF to ON, the default value
(offset or gain value) corre-
sponding to the selected I/O
signal range is transferred to
Adjustment Value Monitor
Area (A572 and A573).
The values in
these words
can be over-
written
directly, with-
out using the
Adjustment
Value Incre-
ment/Decre-
ment Bits.
Indicates the number of val-
ues to be averaged to obtain
the Offset/Gain Value Moni-
tor values in adjustment
mode. The number of sam-
ples can be set between
0000 and 0040 hex (0 to 64).
Set this parameter before
turning ON the Adjustment
Enable Bit.
Adjustment enabled.
• −10 to 10 V:
• 0 to 10 V, 0
• −10 to 10 V:
• 0 to 10 V, 0
FE0C to
01F4 hex
to 5 V, 1 to
5 V: FF38 to
00C8 hex
1194 to
157C hex
to 5 V, 1 to
5 V: 0ED8 to
1068 hex
Section 7-9
User
User
Motion
Control
Module
Motion
Control
Module
Motion
Control
Module or
User
User
User
Controlled
by
221