XW2Z-200J-B10 Omron, XW2Z-200J-B10 Datasheet - Page 335

no-image

XW2Z-200J-B10

Manufacturer Part Number
XW2Z-200J-B10
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B10

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB10
Sync Cycle Time
Sync Mode
Startup Mode Setting (CX-Programmer: Startup Tab Page)
Startup Mode
Cycle Time Settings (CX-Programmer: Timer/Peripheral Service)
Cycle Time
Watch Cycle Time
312
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
+319
+319
+81
+307
+308
Word
Word
Word
Word
Word
Address
Address
Address
Address
Address
00 to 14 0000 hex: Default (Coordina-
15
00 to 11 00 hex: PROGRAM mode
15
00 to 15 0001 to 03E8 hex: 0.1 to
00 to 15 0001 to 0064 hex: 1 to 100
Bits
Bits
Bits
Bits
Bits
0: Sync mode
tor Module cycle time)
0001 to 0064 hex: 0.1 to 10.0
ms (unit: 0.1 ms)
Default: Coordinator Module
cycle time
1: Async mode
Default: Sync mode
01 hex: MONITOR mode
02 hex: RUN mode
00: Setting disabled
01: Setting enabled
Default: Setting disabled
100.0 ms (unit: 0.1 ms)
Default: 0000 hex (variable
cycle time)
ms (unit: 0.1 ms)
Default: 0000 hex (50 ms)
Settings
Settings
Settings
Settings
Settings
Sets the cycle time for the Coordinator
Module when high-speed synced oper-
ation is to be used only between Motion
Control Modules.
Sets either Sync Mode or Async Mode.
Sync Mode is used to sync operation
between the Coordinator Module and
Motion Control Modules.
Async Mode is convenient for debug-
ging Motion Control Modules even if
Sync Mode is to be used for actual
operation.
Sets the mode in which the Coordinator
Module will start. The mode set here
can also be enabled and disabled. If
this setting is disabled, the Coordinator
Module will start in RUN mode.
Set to 0001 to 03E8 hex to specify a
constant (minimum) cycle time. If the
cycle time is less than this setting, it will
be extended until this time passes.
Leave this setting at 0000 for a variable
cycle time.
Change this setting only when you want
to change the default maximum cycle
time. The Cycle Time Too Long Flag
(A401.08) will be turned ON if the
actual cycle time exceeds this setting.
Function
Function
Function
Function
Function
A404.06 (Sync Cycle
Time Too Long Flag)
---
---
A404.05 (Constant
Cycle Time Exceeded
Flag)
A208 to A209 (Present
Cycle Time)
Related flags and
Related flags and
Related flags and
Related flags and
Related flags and
words
words
words
words
words
At power ON
At start of opera-
tion (cannot be
changed during
operation)
At start of opera-
tion (cannot be
changed during
operation)
At power ON
At power ON
Appendix C
When setting is
When setting is
When setting is
When setting is
When setting is
read
read
read
read
read