XW2Z-200J-B10 Omron, XW2Z-200J-B10 Datasheet - Page 378

no-image

XW2Z-200J-B10

Manufacturer Part Number
XW2Z-200J-B10
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B10

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB10
Auxiliary Area Allocations
Address
A606 to
A607
A608
A609
00 to 15 High-
00
01
03
04
05
06
07
08
12
00
01
03
04
05
06
07
08
12
Bits
speed
Counter
2
High-
speed
counter 1
status
High-
speed
counter 2
status
For following
counter modes
• Absolute linear
• Absolute circular
• Absolute linear
For following
counter modes
• Linear counter
• Circular counter
Target Comparison In-progress Flag
PV Overflow/Underflow Flag
Phase Z Input Reset Flag (ON for
one cycle)
Absolute No. of Rotations Read Error
Flag
Absolute No. of Rotations Read
Completed Flag
Measuring Flag (measurement mode
1 or 2)
Note Valid when Counter Data Dis-
play in System Setup is set to
Counter Movements (mode 1) or Fre-
quency (mode 2).
High-speed Counter Operating Flag
Count Latched Flag
Absolute Offset Preset Error Flag
Target Comparison In-progress Flag
PV Overflow/Underflow Flag
Phase Z Input Reset Flag (ON for
one cycle)
Absolute No. of Rotations Read Error
Flag
Absolute No. of Rotations Read
Completed Flag
Measuring Flag (measurement mode
1 or 2)
High-speed Counter Operating Flag
Count Latched Flag
Absolute Offset Preset Error Flag
(CW − )
(CW+)
Name
PV of absolute
number of rota-
tions
Monitor data
Same as for A604 and A605 for high-speed counter 1 except that
measuring the high-speed counter frequency is not possible for
high-speed counter 2.
OFF: Target value comparison is not being performed for
CTBL(882).
Note This flag is always OFF for range comparison.
ON: Target value comparison is being performed for CTBL(882).
Note Target comparison is continued without interruption once it
has been started (as opposed to range comparison), so this flag
can be used to check whether target comparison is in progress.
OFF: There is no counter overflow or underflow in Linear Counter
Mode. This flag will always be OFF in Circular Counter Mode.
ON: There is a counter overflow or underflow in Linear Counter
Mode. The counter PV will be fixed at the overflow or underflow
limit. This flag will be cleared when the High-speed Counter Start
Bit is turned OFF.
ON for one cycle when the counter PV is reset with the counter
reset method set to a phase Z + software reset.
Note This flag will turn ON for one cycle after the counter PV is
reset if the phase Z signal (reset input) turns ON while the High-
speed Counter Reset Bit (A610.01) is ON.
OFF: No error
ON: Error
OFF: Rotations being read or reading has not been executed.
ON: Reading has been completed (Turned ON when serial recep-
tion of the number of rotations has been completed.)
OFF: Changes in the counter PV or the counter frequency is not
being measured.
ON: Changes in the counter PV or the counter frequency is being
measured.
In measurement mode 1, this flag will turn ON at the beginning of
the sampling time after the Measurement Start Bit (A610.02) is
turned ON.
OFF: Counter is not operating.
ON: Counter is operating.
OFF: Count has not been latched.
ON: Latching the count has been completed for the latch input.
OFF: No error occurred when saving the absolute offset.
ON: An error occurred when saving the absolute offset.
Same as for high-speed counter 1.
Function
Appendix D
355