Basic Operating Procedure
4. Turning ON Power and Checking Initial Operation
5. System Setup
Settings
6. Writing the
Programs
16
1,2,3...
Note
Note
The System Setup and user programs are backed up in built-in flash memory.
When the data is being backed up, a message indicating the data is being
transferred will be displayed on the CX-Programmer. Never turn OFF the
power supply to the FQM1 while data is being backed up.
These settings determine the Modules’ software configuration. Refer to
Appendix C System Setup, Auxiliary Area Allocations, and Built-in I/O Alloca-
tions for details.
The FQM1 is set to the Sync Mode by default. This mode must be changed on
the Coordinator Module when programming Motion Control Modules, transfer-
ring programs, or debugging. Set the mode to ASync Mode in the System
Setup of the Coordinator Module to enable changing the operating modes of
the Motion Control Modules and creating programs directly from the CX-Pro-
grammer.
Write each program with the CX-Programmer, including one cyclic task and
the required number of interrupt tasks.
1. Add Motion Control Modules to the tree by executing Insert - PC once for
2. When going online to Motion Control Modules through the Coordinator
each Motion Control Module connected to the Coordinator Module.
Module, the node set for the FINS destination address in the network set-
tings on the Change PC Type Window determines the Motion Control Mod-
ule that is connected. Normally the node number is automatically allocated
for the Motion Control Module when Insert - PC is executed.
Section 1-6