XW2Z-200J-B10 Omron, XW2Z-200J-B10 Datasheet - Page 380

no-image

XW2Z-200J-B10

Manufacturer Part Number
XW2Z-200J-B10
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B10

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB10
Auxiliary Area Allocations
Address
A612
A613
A614
A615
A620 to
A621
A622 to
A623
A624
A625
00 to 15 High-
00 to 15
00 to 15 High-
00 to 15
00 to 15 Pulse Output 1 PV
00 to 15 Pulse Output 2 PV
00
01
02
03
04
05
06
07
00
01
02
03
04
05
06
07
Bits
speed
counter 1
monitor
data
speed
counter 2
monitor
data
Note This item applies when the operation
mode is relative pulse output, absolute pulse
output in linear mode, absolute pulse output in
circular mode, or electronic cam mode.
One-shot Pulse Output 1 ON Time
Note This item applies when the operation
mode is one-shot output mode.
Pulse Time Measurement 1
Note This item applies when the operation
mode is time measurement mode using a pulse
counter.
One-shot Pulse Output 2 ON Time
Pulse Time Measurement 2
Pulse
Output 1
Status
Pulse
Output 2
Status
Range Comparison Execution
Results Flags
Output Bit Pattern
Range Comparison Results
Output Bit Pattern
Pulse Output Completed Flag
Pulse Output Set Flag
Target Frequency Not Reached Flag
Target Comparison Flag
Independent Pulse Output Flag
PLS2 Positioning Flag
Accelerating/Decelerating Flag
Pulse Output Flag
Pulse Output Completed Flag
Pulse Output Set Flag
Target Frequency Not Reached Flag
Target Comparison Flag
Independent Pulse Output Flag
PLS2 Positioning Flag
Accelerating/Decelerating Flag
Pulse Output Flag
Name
Contains the CTBL(882) execution results for range comparison.
Bits 00 to 15 correspond to ranges 1 to 16.
OFF: No match
ON: Match
Contains the output bit pattern when a match is found for
CTBL(882) execution results for range comparison
Note If more than one match is found, an OR of the output bit
patterns with matches will be stored here.
Same as for high-speed counter 1 monitor data.
Contains the pulse output PV as an 8-digit hexadecimal number.
Relative mode: 00000000 to FFFFFFFF hex
Absolute linear mode: 80000000 to 7FFFFFFF hex
Absolute circular mode: 00000000 to circular maximum count
Contains the time that the one-shot pulse output has been ON as
an 8-digit hexadecimal number.
0000 0000 to 0000 270F (unit: set by STIM(980))
Contains the time measured by the pulse counter as an 8-digit
hexadecimal number.
0000 0000 to FFFF FFFF hex (unit: set by STIM(980))
Same as for Pulse Output 1 PV.
Same as for One-shot Pulse Output 1 ON time.
Same as for Pulse Time Measurement 1.
OFF: Pulse output not completed (OFF during pulse output).
ON: Pulse output completed (ON when pulse distribution has
been completed).
OFF: Pulse output amount not set by PULS(886).
ON: Pulse output amount set by PULS(886).
OFF: Target speed has been reached during pulse output for
PLS2(887).
ON: Decelerated before reaching the target speed during pulse
output for PLS2(887).
OFF: Comparison stopped.
ON: Comparison in progress.
OFF: Pulses not being output or being output continuously.
ON: Pulses being output.
OFF: Not positioning.
ON: Positioning in progress.
OFF: No output or constant-speed output.
ON: Acceleration or deceleration in progress for ACC(888) or
PLS2(887).
OFF: Pulse output stopped.
ON: Pulse output in progress.
Same as for Pulse Output 1 Status.
Function
Appendix D
357