AT32UC3A4128S Atmel Corporation, AT32UC3A4128S Datasheet - Page 54

no-image

AT32UC3A4128S

Manufacturer Part Number
AT32UC3A4128S
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A4128S

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
Hardware Qtouch Acquisition
No
Usb Transceiver
1
Usb Speed
Hi-Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
2
Uart
4
Sd / Emmc
2
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
AES
Sram (kbytes)
128
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A4128S-C1UR
Manufacturer:
ATMEL
Quantity:
2 620
Part Number:
AT32UC3A4128S-CIUT
Manufacturer:
ATMEL
Quantity:
350
Part Number:
AT32UC3A4128S-CIUT
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT32UC3A4128S-U
Manufacturer:
ATMEL
Quantity:
12 914
Part Number:
AT32UC3A4128SC101
Manufacturer:
STM
Quantity:
6 278
Part Number:
AT32UC3A4128SC1UT
Manufacturer:
ATMEL
Quantity:
6 055
7.5.11.3
7.5.11.4
7.5.12
32072G–11/2011
Calibration Registers
Brown-Out detector 3V3
External reset
The Brown-Out Detector 3V3 (BOD33) monitors one VDDIO supply pin and compares the sup-
ply voltage to the brown-out detection 3V3 level, which is typically calibrated at 2V7. The BOD33
is enabled by default, but can be disabled by software. The Brown-Out Detector 3V3 can either
generate an interrupt or a reset when the supply voltage is below the brown-out detection3V3
level. In any case, the BOD33 output is available in bit POSCSR.BOD33DET bit.
Note that any change to the BOD33.LEVEL field of the BOD33 register should be done with the
BOD33 deactivated to avoid spurious reset or interrupt.
The BOD33.LEVEL default value is calibrated to 2V7
See Electrical Characteristics chapter for parametric details.
Table 7-5.
The external reset detector monitors the state of the RESET_N pin. By default, a low level on
this pin will generate a reset.
The Power Manager controls the calibration of the RC oscillator, voltage regulator, bandgap
voltage reference through several calibrations registers.
Those calibration registers are loaded after a Power On Reset with default values stored in fac-
tory-programmed flash fuses.
Although it is not recommended to override default factory settings, it is still possible to override
these default values by writing to those registers. To prevent unexpected writes due to software
bugs, write access to these registers is protected by a “key”. First, a write to the register must be
made with the field “KEY” equal to 0x55 then a second write must be issued with the “KEY” field
equal to 0xAA.
TFBGA144
H5
VDDIO pin monitored by BOD33
QFP144
81
VFBGA100
E5
54

Related parts for AT32UC3A4128S