tmp86fh09amg TOSHIBA Semiconductor CORPORATION, tmp86fh09amg Datasheet - Page 78

no-image

tmp86fh09amg

Manufacturer Part Number
tmp86fh09amg
Description
8 Bit Microcontroller Tlcs-870/c Series
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmp86fh09amg(C
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp86fh09amg(C,ZHZ
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
8.3
Function
Example 1 :Generating an interrupt 1 ms after the rising edge of the input pulse to the TC1 pin
Example 2 :Generating an interrupt when the low-level pulse with 4 ms or more width is input to the TC1 pin
8.3.2
pin, and counts up at the edge of the internal clock. For the trigger edge used to start counting, either the ris-
ing or falling edge is defined in TC1CR<TC1S>.
width of 12/fc [s] or more is required to ensure edge detection. The rejection circuit is turned off in the
SLOW1/2 or SLEEP1/2 mode, but a pulse width of one machine cycle or more is required.
(fc = 16 MHz)
(fc = 16 MHz)
External Trigger Timer Mode
In the external trigger timer mode, the up-counter starts counting by the input pulse triggering of the TC1
Since the TC1 pin input has the noise rejection, pulses of 4/fc [s] or less are rejected as noise. A pulse
・ When TC1CR<METT1> is set to “1” (trigger start and stop)
・ When TC1CR<METT1> is set to “0” (trigger start)
the up-counter is cleared and halted and an INTTC1 interrupt request is generated.
and the TC1DRA, the up-counter is cleared and halted without generating an interrupt request. There-
fore, this mode can be used to detect exceeding the specified pulse by interrupt.
the up-counter is cleared and halted and an INTTC1 interrupt request is generated.
ing is ignored if detecting it before detecting a match between the up-counter and the TC1DRA.
When a match between the up-counter and the TC1DRA value is detected after the timer starts,
If the edge opposite to trigger edge is detected before detecting a match between the up-counter
After being halted, the up-counter restarts counting when the trigger edge is detected.
When a match between the up-counter and the TC1DRA value is detected after the timer starts,
The edge opposite to the trigger edge has no effect in count up. The trigger edge for the next count-
LDW
DI
SET
EI
LD
LD
LDW
DI
SET
EI
LD
LD
(TC1DRA), 007DH
(EIRL). 7
(TC1CR), 00000100B
(TC1CR), 00100100B
(TC1DRA), 01F4H
(EIRL). 7
(TC1CR), 00000100B
(TC1CR), 01110100B
Page 68
; 1ms ÷ 2
; IMF= “0”
; Enables INTTC1 interrupt
; IMF= “1”
; Selects the source clock and mode
; Starts TC1 external trigger, METT1= 0
; 4 ms ÷ 2
; IMF= “0”
; Enables INTTC1 interrupt
; IMF= “1”
; Selects the source clock and mode
; Starts TC1 external trigger, METT1= 1
7
/fc = 7DH
7
/fc = 1F4H
TMP86FH09AMG