s71ws512ne0bfwzz Meet Spansion Inc., s71ws512ne0bfwzz Datasheet - Page 36

no-image

s71ws512ne0bfwzz

Manufacturer Part Number
s71ws512ne0bfwzz
Description
Stacked Multi-chip Product Mcp Flash Memoy And Psram Cmos 1.8 Volt, Simultaneous Operation, Burst Mode Flash Memory And Pseudo-static Ram
Manufacturer
Meet Spansion Inc.
Datasheet
A d v a n c e
I n f o r m a t i o n
RESET# may be tied to the system reset circuitry. A system reset would thus also
reset the Flash memory, enabling the system to read the boot-up firmware from
the Flash memory.
If RESET# is asserted during a program or erase operation, the device requires
a time of t
+t
(during Embedded Algorithms) before the device is ready to
RP
RP
read data again. If RESET# is asserted when a program or erase operation is not
executing, the reset operation is completed within a time of t
(not during Em-
RP
bedded Algorithms). The system can read data t
after RESET# returns to V
.
RH
IH
Refer to the
"Hardware Reset
(RESET#)" section for RESET# parameters and to
Figure 20
for the timing diagram.
Output Disable Mode
When the OE# input is at V
, output from the device is disabled. The outputs are
IH
placed in the high impedance state.
SecSi™ (Secured Silicon) Sector Flash Memory Region
The SecSi (Secured Silicon) Sector feature provides an extra Flash memory re-
gion that enables permanent part identification through an Electronic Serial
Number (ESN). The SecSi Sector is 256 words in length. All reads outside of the
256 word address range will return non-valid data. The Factory Indicator Bit
(DQ7) is used to indicate whether or not the Factory SecSi Sector is locked when
shipped from the factory. The Customer Indicator Bit (DQ6) is used to indicate
whether or not the Customer SecSi Sector is locked when shipped from the fac-
tory. The Factory SecSi bits are permanently set at the factory and cannot be
changed, which prevents cloning of a factory locked part. This ensures the secu-
rity of the ESN and customer code once the product is shipped to the field.
The Factory portion of the SecSi Sector is locked when shipped and the Customer
SecSi Sector that is either locked or is lockable. The Factory SecSi Sector is al-
ways protected when shipped from the factory, and has the Factory Indicator Bit
(DQ7) permanently set to a “1”. The Customer SecSi Sector is typically shipped
unprotected, allowing customers to utilize that sector in any manner they choose.
The Customer Indicator Bit set to “0.” Once the Customer SecSi Sector area is
protected, the Customer Indicator Bit will be permanently set to “1.”
The system accesses the SecSi Sector through a command sequence (see the
"Enter SecSi™ Sector/Exit SecSi Sector Command
Sequence" section). After the
system has written the Enter SecSi Sector command sequence, it may read the
SecSi Sector by using the addresses normally occupied by the memory array. This
mode of operation continues until the system issues the Exit SecSi Sector com-
mand sequence, or until power is removed from the device. While SecSi Sector
access is enabled, Memory Array read access, program operations, and erase op-
erations to all sectors other than SA0 are also available. On power-up, or
following a hardware reset, the device reverts to sending commands to the nor-
mal address space.
Factory Locked: Factor SecSi Sector Programmed and Protected
At the Factory
In a factory sector locked device, the Factory SecSi Sector is protected when the
device is shipped from the factory. The Factory SecSi Sector cannot be modified
in any way. The device is pre programmed with both a random number and a se-
cure ESN. The Factory SecSi Sector is located at addresses 000000h–00007Fh.
The device is available pre programmed with one of the following:
36
S29WSxxxN MirrorBit™ Flash Family For Multi-chip Products (MCP) S71WS512NE0BFWZZ_00_ A1 June 28, 2004

Related parts for s71ws512ne0bfwzz