s71ws512ne0bfwzz Meet Spansion Inc., s71ws512ne0bfwzz Datasheet - Page 38

no-image

s71ws512ne0bfwzz

Manufacturer Part Number
s71ws512ne0bfwzz
Description
Stacked Multi-chip Product Mcp Flash Memoy And Psram Cmos 1.8 Volt, Simultaneous Operation, Burst Mode Flash Memory And Pseudo-static Ram
Manufacturer
Meet Spansion Inc.
Datasheet
Not supported due to page programming requirement
38
Addresses
Addresses
1Ch
1Dh
10h
11h
12h
13h
14h
15h
16h
17h
18h
19h
1Ah
1Bh
1Eh
1Fh
20h
21h
22h
23h
24h
25h
26h
through
within the bank, will return non-valid data. Reads from other banks are allowed,
writes are not. To terminate reading CFI data, the system must write the reset
command.
The system can also write the CFI query command when the device is in the au-
toselect mode. The device enters the CFI query mode, and the system can read
CFI data at the addresses given in
write the reset command to return the device to the autoselect mode.
For further information, please refer to the CFI Specification and CFI Publication
100. Please contact your sales office for copies of these documents.
Table 11
0051h
0052h
0059h
0002h
0000h
0040h
0000h
0000h
0000h
0000h
0000h
0017h
0019h
0000h
0000h
0005h
0009h
0008h
0000h
0003h
0001h
0003h
0000h
Data
Data
S29WSxxxN MirrorBit™ Flash Family For Multi-chip Products (MCP) S71WS512NE0BFWZZ_00_ A1 June 28, 2004
within that bank. All reads outside of the CFI address range,
Table 8. CFI Query Identification String
Table 9. System Interface String
Typical timeout for Min. size buffer write 2
Max. timeout for full chip erase 2
A d v a n c e
Address for Alternate OEM Extended Table (00h = none exists)
Typical timeout for full chip erase 2
Max. timeout for byte/word write 2
Typical timeout per single byte/word write 2
Max. timeout per individual block erase 2
Max. timeout for buffer write 2
Table 8
Alternate OEM Command Set (00h = none exists)
Typical timeout per individual block erase 2
V
V
PP
PP
DQ7–DQ4: volt, DQ3–DQ0: 100 millivolt
DQ7–DQ4: volt, DQ3–DQ0: 100 millivolt
Max. voltage (00h = no V
Min. voltage (00h = no V
Address for Primary Extended Table
Query Unique ASCII string “QRY”
through
I n f o r m a t i o n
Primary OEM Command Set
V
V
CC
CC
Max. (write/erase)
Min. (write/erase)
Table
Description
Description
N
times typical (00h = not supported)
11. The system must
N
N
N
µs (00h = not supported)
ms (00h = not supported)
times typical
N
PP
PP
times typical
pin present)
pin present)
N
times typical
N
µs
(Note )
N
(Note )
ms
(Note )
(Note )

Related parts for s71ws512ne0bfwzz