PEB2256E INFINEON [Infineon Technologies AG], PEB2256E Datasheet - Page 184

no-image

PEB2256E

Manufacturer Part Number
PEB2256E
Description
E1/T1/J1 Framer and Line Interface Component for Long and Short Haul Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet
5.6.4
The local loop-back mode, selected by LIM0.LL = 1, disconnects the receive lines RL1/
2 or RDIP/RDIN from the receiver. Instead of the signals coming from the line the data
provided by system interface are routed through the analog receiver back to the system
interface. However, the bit stream is transmitted undisturbedly on the line. An AIS to the
distant end can be enabled by setting FMR1.XAIS without influencing the data looped
back to the system interface.
Note that enabling the local loop usually invokes an out of frame error until the receiver
resynchronizes to the new framing. The serial codes for transmitter and receiver have to
be identical.
Figure 74
Data Sheet
RL1
RL2
XL1
XL2
Local Loop
Local Loop (T1/J1)
MUX
Clock +
Data
Recovery
AIS-GEN
RCLK
184
Rec.
Framer
Trans.
Framer
Functional Description T1/J1
Elast.
Store
Elast.
Store
FALC56 V1.2
ITS09749
RDO
XDI
PEB 2256
2002-08-27

Related parts for PEB2256E