PEB2256E INFINEON [Infineon Technologies AG], PEB2256E Datasheet - Page 243

no-image

PEB2256E

Manufacturer Part Number
PEB2256E
Description
E1/T1/J1 Framer and Line Interface Component for Long and Short Haul Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet
TSA(8:4)
Idle Channel Code Register (Read/Write)
Value after reset: 00
IDLE
IDL(7:0)
Data Sheet
IDL7
7
Transparent S
0 =
1 =
Idle Channel Code
If channel loop-back is enabled by programming LOOP.ECLB = 1,
the contents of the assigned outgoing channel on ports XL1/XL2 or
XDOP/XDON is set equal to the idle channel code selected by this
register.
Additionally, the specified pattern overwrites the contents of all
channels selected by the idle channel registers ICB(4:1). IDL7 is
transmitted first.
H
The S
The S
signaling controller if enabled and transparently passed
through the FALC56 without any changes. The internal
information of the FALC56 (registers XSW and XSA(8:4)) is
ignored.
a
a
(8:4)-bits are generated internally.
(8:4)-bits are taken from port XDI or from the internal
a
(8:4)-Bit
243
FALC56 V1.2
IDL0
E1 Registers
0
PEB 2256
2002-08-27
(2B)