C8051F700DK Silicon Laboratories Inc, C8051F700DK Datasheet - Page 268

DEV KIT FOR C8051F700

C8051F700DK

Manufacturer Part Number
C8051F700DK
Description
DEV KIT FOR C8051F700
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F700DK

Contents
Board, Cables, CD, Debugger, Power Supply
Processor To Be Evaluated
C8051F7x
Processor Series
C8051F7xx
Interface Type
USB
Operating Supply Voltage
3.3 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F7xx
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1635
C8051F70x/71x
SFR Definition 33.2. TCON: Timer Control
SFR Address = 0x88; SFR Page = All Pages; Bit-Addressable
268
Name
Reset
Bit
Type
7
6
5
4
3
2
1
0
Bit
Name
TR1
TR0
TF1
TF0
IE1
IE0
IT1
IT0
R/W
TF1
7
0
Timer 1 Overflow Flag.
Set to 1 by hardware when Timer 1 overflows. This flag can be cleared by software
but is automatically cleared when the CPU vectors to the Timer 1 interrupt service
routine.
Timer 1 Run Control.
Timer 1 is enabled by setting this bit to 1.
Timer 0 Overflow Flag.
Set to 1 by hardware when Timer 0 overflows. This flag can be cleared by software
but is automatically cleared when the CPU vectors to the Timer 0 interrupt service
routine.
Timer 0 Run Control.
Timer 0 is enabled by setting this bit to 1.
External Interrupt 1.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It
can be cleared by software but is automatically cleared when the CPU vectors to the
External Interrupt 1 service routine in edge-triggered mode.
Interrupt 1 Type Select.
This bit selects whether the configured /INT1 interrupt will be edge or level sensitive.
/INT1 is configured active low or high by the IN1PL bit in the IT01CF register (see
SFR Definition 21.7).
0: /INT1 is level triggered.
1: /INT1 is edge triggered.
External Interrupt 0.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It
can be cleared by software but is automatically cleared when the CPU vectors to the
External Interrupt 0 service routine in edge-triggered mode.
Interrupt 0 Type Select.
This bit selects whether the configured INT0 interrupt will be edge or level sensitive.
INT0 is configured active low or high by the IN0PL bit in register IT01CF (see SFR
Definition 21.7).
0: INT0 is level triggered.
1: INT0 is edge triggered.
R/W
TR1
6
0
R/W
TF0
5
0
TR0
R/W
Rev. 1.0
4
0
Function
R/W
IE1
3
0
R/W
IT1
2
0
R/W
IE0
1
0
R/W
IT0
0
0