HD6417020SVX12I Renesas Electronics America, HD6417020SVX12I Datasheet - Page 274

IC SUPERH MPU ROMLESS 100TQFP

HD6417020SVX12I

Manufacturer Part Number
HD6417020SVX12I
Description
IC SUPERH MPU ROMLESS 100TQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7020r
Datasheet

Specifications of HD6417020SVX12I

Core Processor
SH-1
Core Size
32-Bit
Speed
12.5MHz
Connectivity
EBI/EMI, SCI
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
32
Program Memory Type
ROMless
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417020SVX12I
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6417020SVX12IV
Manufacturer:
RENESAS
Quantity:
63
Part Number:
HD6417020SVX12IV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
10.4.3
In the synchronizing mode, two or more timer counters can be rewritten simultaneously
(synchronized preset). Multiple timer counters can also be cleared simultaneously using TCR
settings (synchronized clear). The synchronizing mode can increase the general registers for a
single time base. All five channels can be set for synchronous operation.
Procedure for Selecting the Synchronizing Mode (figure 10.26):
1. Set 1 in the SYNC bit of the timer synchro register (TSNC) to use the channels in the
2. When a value is written in the TCNT in any of the synchronized channels, the same value is
3. Set the counter to clear with compare match/input capture using bits CCLR1 and CCLR0 in the
4. Set the counter clear source to synchronized clear using the CCLR1 and CCLR0 bits.
5. Set the STR bits in the TSTR to 1 to start counting in the TCNT.
256 RENESAS
synchronizing mode.
simultaneously written in the TCNT in the other channels.
TCR.
Set synchronizing mode
Synchronizing preset
Select synchronizing
Synchronized preset
Synchronizing Mode
Set TCNT
mode
Figure 10.26 Procedure for Selecting the Synchronizing Mode
(2)
(1)
Synchronized clear
generated clear
Select counter
Start counting
Counter clear
Channel that
clear source
source?
Yes
No
(3)
(5)
Synchronized clear
Select counter
Start counting
clear source
(4)
(5)