HD6417750SBP200 Renesas Electronics America, HD6417750SBP200 Datasheet - Page 867

IC SUPERH MPU ROMLESS 256BGA

HD6417750SBP200

Manufacturer Part Number
HD6417750SBP200
Description
IC SUPERH MPU ROMLESS 256BGA
Manufacturer
Renesas Electronics America
Series
SuperH® SH7750r
Datasheet

Specifications of HD6417750SBP200

Core Processor
SH-4
Core Size
32-Bit
Speed
200MHz
Connectivity
EBI/EMI, FIFO, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
28
Program Memory Type
ROMless
Ram Size
24K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 2.07 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
256-BGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417750SBP200
Manufacturer:
HITACHI
0
Part Number:
HD6417750SBP200
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
17.2.4
Bit 4 of SCSSR1 has a different function in smart card interface mode. Coupled with this, the
setting conditions for bit 2 (TEND) are also different.
Note:
Bits 7 to 5: Operate in the same way as for the normal SCI. See section 15, Serial Communication
Interface (SCI), for details.
Bit 4—Error Signal Status (ERS): In smart card interface mode, bit 4 indicates the status of the
error signal sent back from the receiving side during transmission. Framing errors are not detected
in smart card interface mode.
Bit 4: ERS
0
1
Note: Clearing the TE bit in SCSCR1 to 0 does not affect the ERS flag, which retains its previous
Bit 3—Parity Error (PER): Operates in the same way as for the normal SCI. See section 15,
Serial Communication Interface (SCI), for details.
Initial value:
state.
*
Serial Status Register (SCSSR1)
Only 0 can be written, to clear the flag.
R/W:
Bit:
R/(W)*
TDRE
Description
Normal reception, no error signal
[Clearing conditions]
An error signal has been sent from the receiving side indicating detection of
a parity error
[Setting condition]
When the low level of the error signal is detected
7
1
Power-on reset, manual reset, standby mode, or module standby
When 0 is written to ERS after reading ERS = 1
R/(W)*
RDRF
6
0
R/(W)*
ORER
5
0
R/(W)*
FER/
ERS
4
0
Rev.7.00 Oct. 10, 2008 Page 781 of 1074
R/(W)*
PER
3
0
Section 17 Smart Card Interface
TEND
R
2
1
REJ09B0366-0700
R
1
0
(Initial value)
R/W
0
0

Related parts for HD6417750SBP200