QT2032-EKG-1A2 Applied Micro Circuits Corporation, QT2032-EKG-1A2 Datasheet - Page 157

no-image

QT2032-EKG-1A2

Manufacturer Part Number
QT2032-EKG-1A2
Description
Manufacturer
Applied Micro Circuits Corporation
Datasheet

Specifications of QT2032-EKG-1A2

Lead Free Status / RoHS Status
Supplier Unconfirmed
Revision 5.11
0
1
2
3
4
5
6
7
8
9
10
11
15:12
1. This is the Alarm Interrupt Control Register for Register 2.33d (2.21h). It can be used to program which alarms will trip the LASI inter-
Bit
rupt output signal.
WIS Alarms Interrupt Control
LOP-P Enable (RW)
0 = Disabled (default)
1 = Enabled
AIS-P Enable (RW)
0 = Disabled (default)
1 = Enabled
PLM-P Enable (RW)
0 = Disabled (default)
1 = Enabled
LCD-P Enable (RW)
0 = Disabled (default)
1 = Enabled
AIS-L Enable (RW)
0 = Disabled (default)
1 = Enabled
RDI-L Enable (RW)
0 = Disabled (default)
1 = Enabled
LOS Enable (RW)
0 = Disabled (default)
1 = Enabled
LOF Enable (RW)
0 = Disabled (default)
1 = Enabled
Reserved (RO)
Far End LOP-P Enable (RW)
0 = Disabled (default)
1 = Enabled
Far End AIS-P/LOP-P Enable (RW)
0 = Disabled (default)
1 = Enabled
Far End PLM-P/LCD-P Enable (RW)
0 = Disabled (default)
1 = Enabled
SEF Enable (RW)
0 = Disabled (default)
1 = Enabled
Reserved (RO)
AppliedMicro - Confidential & Proprietary
1
- Vendor Specific Register 2.C500h
QT2022/32 - Data Sheet: DS3051
157