Specifications of UJA1066TW/5V0,518

Number Of Transceivers
1
Power Down Mode
Sleep/Standby
Standard Supported
ISO 11898-2
Operating Supply Voltage (min)
5.5V
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
NXP Semiconductors
UJA1066_2
Product data sheet
2.3 Power management
2.4 Fail-safe features
Smart operating modes and power management modes
Cyclic wake-up capability in Standby and Sleep modes
Local wake-up input with cyclic supply feature
Remote wake-up capability via the CAN-bus
External voltage regulators can easily be incorporated into the power supply system
(flexible and fail-safe)
42 V battery-related high-side switch for driving external loads such as relays and
wake-up switches
Intelligent maskable interrupt output
Safe and predictable behavior under all conditions
Programmable fail-safe coded window and time-out watchdog with on-chip oscillator,
guaranteeing autonomous fail-safe system supervision
Fail-safe coded 16-bit SPI interface for the microcontroller
Global enable pin for the control of safety-critical hardware
Detection and detailed reporting of failures:
Rigorous error handling based on diagnostics
Supply failure early warning allows critical data to be stored
23 bits of access-protected RAM available (e.g. for logging cyclic problems)
Reporting in a single SPI message; no assembly of multiple SPI frames needed
Limp-home output signal for activating application hardware in case system enters
Fail-safe mode (e.g. for switching on warning lights)
Fail-safe coded activation of Software development mode and Flash mode
Unique SPI readable device type identification
Software-initiated system reset
On-chip oscillator failure and watchdog alerts
Battery and voltage regulator undervoltages
CAN-bus failures (short circuits and open-circuit bus wires)
TXD and RXD clamping situations and short circuits
Clamped or open reset line
SPI message errors
Overtemperature warning
ECU ground shift (two selectable thresholds)