PSB2186N-V11TR Infineon Technologies, PSB2186N-V11TR Datasheet - Page 83

no-image

PSB2186N-V11TR

Manufacturer Part Number
PSB2186N-V11TR
Description
IC ISDN SUBSCRIB ACCESS 44-PLCC
Manufacturer
Infineon Technologies
Datasheet

Specifications of PSB2186N-V11TR

Controller Type
Subscriber Access Controller (ISDN)
Interface
4-Wire SPI Serial
Voltage - Supply
4.75 V ~ 5.25 V
Current - Supply
17mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
44-PLCC
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Other names
PSB2186N-V11INTR
PSB2186N-V11TR
Reaction of the ISAC-S TE
In the following various possible actions to be taken according to § 5.8.5 parts a) through c)
are discussed separately.
1) I-frame which is not a command an ISTA: PCE-interrupt is generated
2) S-frame with bits 8-5 in Octet 4 = 0 an ISTA: PCE-interrupt is generated
1) S-frame with more than 6 octets an ISTA:PCE-interrupt is generated; the
contents of the additional octets is discarded.
4) A FRMR with not exactly 10 octetsAfter a RME and identifying FRMR by
reading RHCR-register, the software has to
read RBCH, RBCL. If OV = 1 or
RBC11-RBC0 = 0 … 101 then the FRMR did
not have exactly 10 octets.
This condition is automatically checked within the device and in the case of an invalid N(R) an
ISTA:PCE-interrupt is generated. An S-field response is done by the ISAC-S TE in all
prescribed cases of invalid N(R) automatically.
Semiconductor Group
a) There are different types of undefined frames:
b) If the length of the frame is too small 1.1.1b) applies and the frame is invalid. Therefore
c) An invalid N(R) is one that does not meet the condition
incorrect length can only mean:
3) A frame with bits 4-1 in octet 4
4) Frame with bits 2-1 in octet 4 equal
5) SABME, UI, DISC, not a command,
2) Undefined frames with 5 octets,
3) SABME, BM, DISC, UA-frame
equal to "1101" (selective reject)
to "11" but control field not contained
in ISTA: RME interrupt;
DM, UA, FRMR not a response
ISTA: RME interrupt;
bits 2-1 in octet 4 not being equal
to "11" (e.g. modulo 8 S-frame)
with more than 5 octets
V(A) < N(R) < V(S)
83
an ISTA: PCE is generated
the control field can be read afterwards in
RHCR (after having checked for invalid
frame condition).
the control field can be read afterwards in
RHCR, the C/R-bit in the SAPR-register
(after having checked for invalid frame
condition).
an ISTA:PCE-interrupt is generated
after ISTA:
RME and identifying the frame by RHCR the
RSTA:RDA bit is 1 if the frames had more
than 5 octets and 0 if they had exactly 5 octets.
Functional Description