M42800A Atmel Corporation, M42800A Datasheet - Page 193

no-image

M42800A

Manufacturer Part Number
M42800A
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of M42800A

Flash (kbytes)
0 Kbytes
Pin Count
144
Max. Operating Frequency
33 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
54
Ext Interrupts
54
Usb Speed
No
Usb Interface
No
Spi
2
Uart
2
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
8
Self Program Memory
NO
External Bus Interface
1
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3/5.0
Fpu
No
Mpu / Mmu
no / no
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
No
19.12 SPI Status Register
Register Name:
Access Type:
Offset:
Reset Value:
• RDRF: Receive Data Register Full (Code Label SP_RDRF)
0 = No data has been received since the last read of SP_RDR
1= Data has been received and the received data has been transferred from the serializer to SP_RDR since the last read of
SP_RDR.
• TDRE: Transmit Data Register Empty (Code Label SP_TDRE)
0 = Data has been written to SP_TDR and not yet transferred to the serializer.
1 = The last data written in the Transmit Data Register has been transferred in the serializer.
TDRE equals zero when the SPI is disabled or at reset. The SPI enable command sets this bit to one.
• MODF: Mode Fault Error (Code Label SP_MODF)
0 = No Mode Fault has been detected since the last read of SP_SR.
1 = A Mode Fault occurred since the last read of the SP_SR.
• OVRES: Overrun Error Status (Code Label SP_OVRES)
0 = No overrun has been detected since the last read of SP_SR.
1 = An overrun has occurred since the last read of SP_SR.
An overrun occurs when SP_RDR is loaded at least twice from the serializer since the last read of the SP_RDR.
• SPENDRX: End of Receiver Transfer (Code Label SP_SPENDRX)
0 = The End of Transfer signal from the Peripheral Data Controller channel dedicated to the receiver is inactive.
1 = The End of Transfer signal from the Peripheral Data Controller channel dedicated to the receiver is active.
• SPENDTX: End of Transmitter Transfer (Code Label SP_SPENDTX)
0 = The End of Transfer signal from the Peripheral Data Controller channel dedicated to the transmitter is inactive.
1 = The End of Transfer signal from the Peripheral Data Controller channel dedicated to the transmitter is active.
• SPIENS: SPI Enable Status (Code Label SP_SPIENS)
0 = SPI is disabled.
1 = SPI is enabled.
1779D–ATARM–14-Apr-06
31
23
15
7
30
22
14
SP_SR
Read-only
0x10
0x0
6
SPENDTX
29
21
13
5
SPENDRX
28
20
12
4
OVRES
27
19
11
3
MODF
26
18
10
2
AT91M42800A
TDRE
25
17
9
1
SPIENS
RDRF
24
16
8
0
193

Related parts for M42800A