AT32UC3C2512C Automotive Atmel Corporation, AT32UC3C2512C Automotive Datasheet - Page 490

no-image

AT32UC3C2512C Automotive

Manufacturer Part Number
AT32UC3C2512C Automotive
Description
Manufacturer
Atmel Corporation
Table 24-1.
9166C–AVR-08/11
19:17
13:12
11:0
Bit
28
27
26
25
24
23
22
21
20
16
15
14
External address match
Reserved for future use
Specific address register 1 match
Specific address register 2 match
Specific address register 3 match
Specific address register 4 match
Type ID match
VLAN tag detected (i.e., type id of 0x8100)
Priority tag detected (i.e., type id of 0x8100 and null VLAN identifier)
VLAN priority (only valid if bit 21 is set)
Concatenation format indicator (CFI) bit (only valid if bit 21 is set)
End of frame - when set the buffer contains the end of a frame. If end of frame is not set, then the only other valid status
are bits 12, 13 and 14.
Start of frame - when set the buffer contains the start of a frame. If both bits 15 and 14 are set, then the buffer contains a
whole frame.
Receive buffer offset - indicates the number of bytes by which the data in the first buffer is offset from the word address.
Updated with the current values of the network configuration register. If jumbo frame mode is enabled through bit 3 of the
network configuration register, then bits 12 and 13 of the receive buffer descriptor entry are used to indicate bits 12 and 13
of the frame length.
Length of frame including FCS (if selected). Bits 12 and 13 are also used if jumbo frame mode is selected.
Receive Buffer Descriptor Entry (Continued)
To receive frames, the buffer descriptors must be initialized by writing the right address to bits 2
through 31in the first word of each list entry. Bit zero must be written with zero. Bit one is the
wrap bit and indicates the last entry in the list.
The start location of the receive buffer descriptor list must be written to the receive buffer queue
pointer register before setting the receive enable bit in the network control register to enable
receive. As soon as the receive sub-module starts writing received frame data to the receive
FIFO, the receive buffer manager reads the first receive buffer location pointed to by the receive
buffer queue pointer register.
If the filter sub-module indicates that the frame should be copied to memory, the receive data
DMA operation starts writing data into the receive buffer. If an error occurs, the buffer is recov-
ered. If the current buffer pointer has its wrap bit set or is the 1024
buffer location is read from the beginning of the receive descriptor list. Otherwise, the next
receive buffer location is read from the next word in memory.
There is an 11-bit counter to count out the 2048 word locations of a maximum length, receive
buffer descriptor list. This is added with the value originally written to the receive buffer queue
pointer register to produce a pointer into the list. A read of the receive buffer queue pointer reg-
ister returns the pointer value, which is the queue entry currently being accessed. The counter is
reset after receive status is written to a descriptor that has its wrap bit set or rolls over to zero
after 1024 descriptors have been accessed. The value written to the receive buffer pointer regis-
ter may be any word-aligned address, provided that there are at least 2048 word locations
available between the pointer and the top of the memory.
Function
th
descriptor, the next receive
AT32UC3C
490

Related parts for AT32UC3C2512C Automotive