15.9.4 BDLC Data Register
Data Sheet
258
NOTE:
This register is used to pass the data to be transmitted to the J1850 bus from the
CPU to the BDLC. It is also used to pass data received from the J1850 bus to the
CPU. Each data byte (after the first one) should be written only after a Tx data
register empty (TDRE) state is indicated in the BSVR.
Data read from this register is the last data byte received from the J1850 bus. This
received data should only be read after an Rx data register full (RDRF) interrupt
has occurred. (See
The BDR is double buffered via a transmit shadow register and a receive shadow
register. After the byte in the transmit shift register has been transmitted, the byte
currently stored in the transmit shadow register is loaded into the transmit shift
register. Once the transmit shift register has shifted the first bit out, the TDRE flag
is set, and the shadow register is ready to accept the next data byte. The receive
shadow register works similarly. Once a complete byte has been received, the
receive shift register stores the newly received byte into the receive shadow
register. The RDRF flag is set to indicate that a new byte of data has been received.
The programmer has one BDLC byte reception time to read the shadow register
and clear the RDRF flag before the shadow register is overwritten by the newly
received byte.
To abort an in-progress transmission, the programmer should stop loading data
into the BDR. This causes a transmitter underrun error and the BDLC automatically
disables the transmitter on the next non-byte boundary. This means that the
earliest a transmission can be halted is after at least one byte plus two extra logic
1 bits have been transmitted. The receiver picks this up as an error and relays it in
the state vector register as an invalid symbol error.
The extra logic 1 bits are an enhancement to the J1850 protocol which forces a
byte boundary condition fault. This is helpful in preventing noise on the J1850 bus
from corrupting a message.
Address: $00FB
Reset:
Read:
Write:
Byte Data Link Communications (BDLC)
Bit 7
BD7
Figure 15-16. BDLC Data Register (BDR)
15.9.3 BDLC State Vector
BD6
6
BD5
5
Indeterminate after reset
BD4
4
Register.)
BD3
3
M68HC12B Family — Rev. 8.0
BD2
2
BD1
1
MOTOROLA
Bit 0
BD0