at91sam9263 ATMEL Corporation, at91sam9263 Datasheet - Page 694

no-image

at91sam9263

Manufacturer Part Number
at91sam9263
Description
At91 Arm Thumb Microcontrollers
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM9263
Manufacturer:
AT
Quantity:
1
Part Number:
at91sam9263-CJ
Manufacturer:
ATMEL
Quantity:
181
Part Number:
at91sam9263-CU
Manufacturer:
ATMEL
Quantity:
132
Part Number:
at91sam9263-EK
Manufacturer:
Atmel
Quantity:
135
Part Number:
at91sam9263B-CU
Manufacturer:
IDT
Quantity:
1 043
Part Number:
at91sam9263B-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at91sam9263B-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at91sam9263B-CU-100
Manufacturer:
ATMEL
Quantity:
1 000
Part Number:
at91sam9263B-CU-100
Manufacturer:
ATMEL
Quantity:
3 060
Part Number:
at91sam9263B-CU-100
Manufacturer:
Atmel
Quantity:
10 000
1 = CAN controller is in bus-off mode
This flag is set depending on TEC counter value. A node is bus off when TEC counter is greater or equal to 256 (decimal).
This flag is automatically reset when above condition is not satisfied.
• SLEEP: CAN controller in Low power Mode
0 = CAN controller is not in low power mode.
1 = CAN controller is in low power mode.
This flag is automatically reset when Low power mode is disabled
• WAKEUP: CAN controller is not in Low power Mode
0 = CAN controller is in low power mode.
1 = CAN controller is not in low power mode.
When a WAKEUP event occurs, the CAN controller is synchronized with the bus activity. Messages can be transmitted or
received. The CAN controller clock must be available when a WAKEUP event occurs. This flag is automatically reset when
the CAN Controller enters Low Power mode.
• TOVF: Timer Overflow
0 = The timer has not rolled-over FFFFh to 0000h.
1 = The timer rolls-over FFFFh to 0000h.
This flag is automatically cleared by reading CAN_SR register.
• TSTP Timestamp
0 = No bus activity has been detected.
1 = A start of frame or an end of frame has been detected (according to the TEOF field in the CAN_MR register).
This flag is automatically cleared by reading the CAN_SR register.
• CERR: Mailbox CRC Error
0 = No CRC error occurred during a previous transfer.
1 = A CRC error occurred during a previous transfer.
A CRC error has been detected during last reception.
This flag is automatically cleared by reading CAN_SR register.
• SERR: Mailbox Stuffing Error
0 = No stuffing error occurred during a previous transfer.
1 = A stuffing error occurred during a previous transfer.
A form error results from the detection of more than five consecutive bit with the same polarity.
This flag is automatically cleared by reading CAN_SR register.
• AERR: Acknowledgment Error
0 = No acknowledgment error occurred during a previous transfer.
1 = An acknowledgment error occurred during a previous transfer.
AT91SAM9263 Preliminary
694
6249D–ATARM–20-Dec-07

Related parts for at91sam9263