LPC1112FHN33/203,5 NXP Semiconductors, LPC1112FHN33/203,5 Datasheet - Page 271

no-image

LPC1112FHN33/203,5

Manufacturer Part Number
LPC1112FHN33/203,5
Description
ARM Microcontrollers - MCU Cortex-M0 16kB flash up to 4 kB SRAM
Manufacturer
NXP Semiconductors
Datasheet

Specifications of LPC1112FHN33/203,5

Rohs
yes
Core
ARM Cortex M0
Processor Series
LPC1112
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
16 KB
Data Ram Size
4 KB
On-chip Adc
Yes
Operating Supply Voltage
1.8 V to 3.6 V
Operating Temperature Range
- 65 C to + 150 C
Package / Case
HVQFN-33
Mounting Style
SMD/SMT
Factory Pack Quantity
260
NXP Semiconductors
UM10398
User manual
15.11.7.4 State: 0x58
15.11.8.1 State: 0x60
15.11.8.2 State: 0x68
15.11.8.3 State: 0x70
15.11.8 Slave Receiver states
Data has been received, NOT ACK has been returned. Data will be read from DAT. A
STOP condition will be transmitted.
Own Slave Address + Write has been received, ACK has been returned. Data will be
received and ACK returned.
Arbitration has been lost in Slave Address and R/W bit as bus Master. Own Slave Address
+ Write has been received, ACK has been returned. Data will be received and ACK will be
returned. STA is set to restart Master mode after the bus is free again.
General call has been received, ACK has been returned. Data will be received and ACK
returned.
4. Exit
5. Write 0x04 to CONSET to set the AA bit.
6. Write 0x08 to CONCLR to clear the SI flag.
7. Increment Master Receive buffer pointer
8. Exit
1. Read data byte from DAT into Master Receive buffer.
2. Write 0x14 to CONSET to set the STO and AA bits.
3. Write 0x08 to CONCLR to clear the SI flag.
4. Exit
1. Write 0x04 to CONSET to set the AA bit.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Set up Slave Receive mode data buffer.
4. Initialize Slave data counter.
5. Exit
1. Write 0x24 to CONSET to set the STA and AA bits.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Set up Slave Receive mode data buffer.
4. Initialize Slave data counter.
5. Exit.
1. Write 0x04 to CONSET to set the AA bit.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Set up Slave Receive mode data buffer.
All information provided in this document is subject to legal disclaimers.
Rev. 12 — 24 September 2012
Chapter 15: LPC111x/LPC11Cxx I2C-bus controller
UM10398
© NXP B.V. 2012. All rights reserved.
271 of 538