HD6417706 RENESAS [Renesas Technology Corp], HD6417706 Datasheet - Page 439

no-image

HD6417706

Manufacturer Part Number
HD6417706
Description
Renesas 32-Bit RISC Microcomputer Super RISC engine Family/SH7700 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417706
Manufacturer:
TDK
Quantity:
500
Part Number:
HD6417706
Manufacturer:
TOSH
Quantity:
1 000
Part Number:
HD6417706-SH3-133V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706BP133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706BP133V
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6417706F120DV
Manufacturer:
HITACHI
Quantity:
96
Part Number:
HD6417706F120DV
Manufacturer:
RENESAS/PBF
Quantity:
375
Part Number:
HD6417706F120DV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133V
Manufacturer:
EDISON
Quantity:
2 000
Part Number:
HD6417706F133V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
HD6417706F133V
Quantity:
27
Receiving Serial Data (Clock Synchronous Mode): Figure 14.21 shows a sample flowchart for
receiving serial data. Serial data reception should be carried out in the procedure described below
after setting the SCI in a reception-enabled state. When switching from the asynchronous mode to
the clock synchronous mode, make sure that ORER, PER, and FER are cleared to 0. If PER or
FER is set to 1, the RDRF bit will not be set and both transmitting and receiving will be disabled.
1. Receive error processing: If a receive error occurs, read the ORER bit in
2. SCI status check and receive data read: Read the SCSSR, check that RDRF is
3. To continue receiving serial data: Read SCRDR, and clear RDRF to 0 before the
Figure 14.21 Sample Flowchart for Serial Data Receiving
No
SCSSR to identify the error. After executing the necessary error processing,
clear ORER to 0. Transmitting/receiving cannot resume if ORER remains set to 1.
set to 1, then read receive data from the SCRDR and clear RDRF to 0. The RXI
interrupt can also be used to determine if the RDRF bit has changed from 0 to 1.
frame MSB (bit 7) of the current frame is received.
No
Read receive data in SCRDR and
clear RDRF bit in SCSSR to 0
Clear RE bit in SCSCR to 0
Read ORER bit in SCSSR
Read RDRF bit in SCSSR
All data received?
Start reception
End reception
ORER = 1?
RDRF = 1?
No
Yes
Yes
Yes
No
Clear ORER bit in SCSSR to 0
Overrun error processing
Error processing
ORER = 1?
Rev. 4.00, 03/04, page 393 of 660