HD6417708SF60 Renesas Electronics America, HD6417708SF60 Datasheet - Page 343

IC SUPERH MPU ROMLESS 144LQFP

HD6417708SF60

Manufacturer Part Number
HD6417708SF60
Description
IC SUPERH MPU ROMLESS 144LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417708SF60

Core Processor
SH-2
Core Size
32-Bit
Speed
60MHz
Connectivity
EBI/EMI, SCI, SmartCard
Peripherals
POR, WDT
Number Of I /o
8
Program Memory Type
ROMless
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Ram Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417708SF60
Manufacturer:
HITACHI
Quantity:
2 400
Part Number:
HD6417708SF60
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417708SF60
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6417708SF60
Manufacturer:
HIT
Quantity:
330
Part Number:
HD6417708SF60I
Manufacturer:
ACCMICRO
Quantity:
144
Part Number:
HD6417708SF60V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417708SF60V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
R64CNT is not initialized by a power-on reset or manual reset, or in standby mode.
Bit 7 always reads 0.
12.2.2
The second counter (RSECCNT) is an 8-bit read/write register used for setting/counting in the
BCD-coded second section of the RTC. The count operation is performed by a carry for each
second of the 64 Hz counter.
The range that can be set is 00–59 (decimal). Errant operation will result if any other value is set.
Carry out write processing after halting the count operation with the START bit in RCR2, or
perform a write using the carry flag as shown in figure 12.2.
RSECCNT is not initialized by a power-on reset or manual reset, or in standby mode.
12.2.3
The minute counter (RMINCNT) is an 8-bit read/write register used for setting/counting in the
BCD-coded minute section of the RTC. The count operation is performed by a carry for each
minute of the second counter.
The range that can be set is 00–59 (decimal). Errant operation will result if any other value is set.
Carry out write processing after halting the count operation with the START bit in RCR2, or
perform a write using the carry flag as shown in figure 12.2.
Initial value:
Initial value:
Bit name:
Bit name:
Second Counter (RSECCNT)
Minute Counter (RMINCNT)
R/W:
R/W:
Bit:
Bit:
7
0
R
7
0
R
R/W
1Hz
6
R
6
10 seconds
R/W
2Hz
5
R
5
R/W
4Hz
4
R
4
R/W
8Hz
3
R
3
16Hz
R/W
2
R
2
1 second
32Hz
R/W
1
R
1
64Hz
R/W
0
R
0
323

Related parts for HD6417708SF60