HD6417708SF60 Renesas Electronics America, HD6417708SF60 Datasheet - Page 436

IC SUPERH MPU ROMLESS 144LQFP

HD6417708SF60

Manufacturer Part Number
HD6417708SF60
Description
IC SUPERH MPU ROMLESS 144LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417708SF60

Core Processor
SH-2
Core Size
32-Bit
Speed
60MHz
Connectivity
EBI/EMI, SCI, SmartCard
Peripherals
POR, WDT
Number Of I /o
8
Program Memory Type
ROMless
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Ram Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417708SF60
Manufacturer:
HITACHI
Quantity:
2 400
Part Number:
HD6417708SF60
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417708SF60
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6417708SF60
Manufacturer:
HIT
Quantity:
330
Part Number:
HD6417708SF60I
Manufacturer:
ACCMICRO
Quantity:
144
Part Number:
HD6417708SF60V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417708SF60V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Serial Data Reception: The handling procedures in the smart card mode are the same as in
ordinary SCI processing. The reception processing flowchart is shown in figure 14.7.
1. Initialize the smart card interface mode as described above in Initialization and in figure 14.5.
2. Check that the ORER and PER flags in SCSSR are cleared to 0. If either flag is set, clear both
to 0 after performing the appropriate error handling procedures.
3. Repeat steps 2 and 3 until the RDRF flag is set to 1.
4. Read the receive data from SCRDR.
5. To receive more data, clear the RDRF flag to 0 and return to step 2.
6. To end reception, clear the RE bit to 0.
This processing can be interrupted. When the RIE bit is set to 1 and interrupt requests are enabled,
a receive-data-full interrupt (RXI) will be requested when the RDRF flag is set to 1 at the end of
the reception. When an error occurs during reception and either the ORER or PER flag is set to 1,
a communication error interrupt (ERI) will be requested. See Interrupt Operation, below, for more
information.
The received data will be transferred to SCRDR even when a parity error occurs during reception
and PER is set to 1, so this data can still be read.
416

Related parts for HD6417708SF60