UPD70F3714GC-8BS-A Renesas Electronics America, UPD70F3714GC-8BS-A Datasheet - Page 379

no-image

UPD70F3714GC-8BS-A

Manufacturer Part Number
UPD70F3714GC-8BS-A
Description
MCU 32BIT V850ES/LX2 64-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Ix2r
Datasheet

Specifications of UPD70F3714GC-8BS-A

Core Processor
RISC
Core Size
32-Bit
Speed
20MHz
Connectivity
CSI, UART/USART
Peripherals
LVD, PWM, WDT
Number Of I /o
39
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
6K x 8
Voltage - Supply (vcc/vdd)
3.5 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3714GC-8BS-A
Manufacturer:
Renesas Electronics America
Quantity:
10 000
9.4
9.4.1
(1) Outline of 6-phase PWM output
Operation
The 6-phase PWM output mode is used to generate a 6-phase PWM output wave, by using TMQ1 and the
TMQ1 option in combination.
The 6-phase PWM output mode is enabled by setting the TQ1CTL1.TQ1MD2 to TQ1CTL1.TQ1MD0 bits of
TMQ1 to “111”.
One 16-bit counter and four 16-bit compare registers of TMQ1 are used to generate a basic 3-phase wave.
The functions of the compare registers are as follows.
TMP1 can perform a tuning operation with TMQ1 to start a conversion trigger source for A/D converters 0 and
1.
Remark
A dead-time interval is generated from the basic 3-phase wave generated by using three 10-bit dead-time
counters and one compare register to create a wave with a reverse phase to that of the basic 3-phase wave.
Then a 6-phase PWM output wave (U, U, V, V, W, and W) is generated.
The 16-bit counter for generating the basic 3-phase wave counts up or down. After the operation has been
started, this counter counts up. When its count value matches the cycle set to the TQ1CCR0 register, the
counter starts counting down. When the count value matches 0001H, the counter counts up again. This
means that a value two times higher than the value set to the TQ1CCR0 register + 1 is the carrier cycle.
10-bit dead-time counters 1 to 3 that generate the dead-time interval count up. Therefore, the value set to the
TMQ1 dead-time compare register (TQ1DTC) is used as a dead-time value as is. Because three counters are
used, dead time can be generated independently in phases U, V, and W. However, because there is only one
register that specifies a dead-time value (TQ1DTC), the same dead-time value is used in the three phases.
System outline
TQ1CCR0 register
TQ1CCR1 register
TQ1CCR2 register
TQ1CCR3 register
Compare Register
m = Set value of TQ1CCR0 register
i = Set value of TQ1CCR1 register
j = Set value of TQ1CCR2 register
k = Set value of TQ1CCR3 register
CHAPTER 9 MOTOR CONTROL FUNCTION
Setting of cycle
Specifying output width of phase U
Specifying output width of phase V
Specifying output width of phase W
User’s Manual U17716EJ2V0UD
Function
0002H ≤ m ≤ FFFEH
0000H ≤ i ≤ m + 1
0000H ≤ j ≤ m + 1
0000H ≤ k ≤ m + 1
Settable Range
377