AT90USB647-MU Atmel, AT90USB647-MU Datasheet - Page 239

no-image

AT90USB647-MU

Manufacturer Part Number
AT90USB647-MU
Description
MCU, 8BIT, 64K FLASH, USB, 64QFN
Manufacturer
Atmel
Datasheets

Specifications of AT90USB647-MU

Controller Family/series
AT90
No. Of I/o's
48
Eeprom Memory Size
2KB
Ram Memory Size
4KB
Cpu Speed
16MHz
No. Of
RoHS Compliant
Core Size
8bit
Program Memory Size
64KB
Oscillator Type
External, Internal
Package
64QFN EP
Device Core
AVR
Family Name
AT90
Maximum Speed
20 MHz
Ram Size
4 KB
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
48
Interface Type
SPI/TWI/USART/USB
On-chip Adc
8-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90USB647-MU
Manufacturer:
AAT
Quantity:
18 240
Part Number:
AT90USB647-MUR
Manufacturer:
AD
Quantity:
2 747
Table 20-5.
7593K–AVR–11/09
Status Code
(TWSR)
Prescaler Bits
are 0
0x60
0x68
0x70
0x78
0x80
0x88
0x90
0x98
0xA0
Status of the 2-wire Serial Bus
and 2-wire Serial Interface Hard-
ware
Own SLA+W has been received;
ACK has been returned
Arbitration lost in SLA+R/W as
Master; own SLA+W has been
received; ACK has been returned
General call address has been
received; ACK has been returned
Arbitration lost in SLA+R/W as
Master; General call address has
been received; ACK has been
returned
Previously addressed with own
SLA+W; data has been received;
ACK has been returned
Previously addressed with own
SLA+W; data has been received;
NOT ACK has been returned
Previously addressed with
general call; data has been re-
ceived; ACK has been returned
Previously addressed with
general call; data has been
received; NOT ACK has been
returned
A STOP condition or repeated
START condition has been
received while still addressed as
Slave
Status Codes for Slave Receiver Mode
To/from TWDR
No TWDR action or
No TWDR action
No TWDR action or
No TWDR action
No TWDR action or
No TWDR action
No TWDR action or
No TWDR action
Read data byte or
Read data byte
Read data byte or
Read data byte or
Read data byte or
Read data byte
Read data byte or
Read data byte
Read data byte or
Read data byte or
Read data byte or
Read data byte
No action
Application Software Response
STA
X
X
X
X
X
X
X
X
X
X
0
0
1
1
X
X
0
0
1
1
0
0
1
1
STO
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
To TWCR
TWIN
T
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
TWE
A
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Next Action Taken by TWI Hardware
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA;
a START condition will be transmitted when the bus
becomes free
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”;
a START condition will be transmitted when the bus
becomes free
Data byte will be received and NOT ACK will be
returned
Data byte will be received and ACK will be returned
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA;
a START condition will be transmitted when the bus
becomes free
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”;
a START condition will be transmitted when the bus
becomes free
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”
Switched to the not addressed Slave mode;
no recognition of own SLA or GCA;
a START condition will be transmitted when the bus
becomes free
Switched to the not addressed Slave mode;
own SLA will be recognized;
GCA will be recognized if TWGCE = “1”;
a START condition will be transmitted when the bus
becomes free
AT90USB64/128