AT90USB647-MU Atmel, AT90USB647-MU Datasheet - Page 375

no-image

AT90USB647-MU

Manufacturer Part Number
AT90USB647-MU
Description
MCU, 8BIT, 64K FLASH, USB, 64QFN
Manufacturer
Atmel
Datasheets

Specifications of AT90USB647-MU

Controller Family/series
AT90
No. Of I/o's
48
Eeprom Memory Size
2KB
Ram Memory Size
4KB
Cpu Speed
16MHz
No. Of
RoHS Compliant
Core Size
8bit
Program Memory Size
64KB
Oscillator Type
External, Internal
Package
64QFN EP
Device Core
AVR
Family Name
AT90
Maximum Speed
20 MHz
Ram Size
4 KB
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
48
Interface Type
SPI/TWI/USART/USB
On-chip Adc
8-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90USB647-MU
Manufacturer:
AAT
Quantity:
18 240
Part Number:
AT90USB647-MUR
Manufacturer:
AD
Quantity:
2 747
29.6.5
7593K–AVR–11/09
Programming the EEPROM
Figure 29-3. Programming the Flash Waveforms
Note:
The EEPROM is organized in pages, see
EEPROM, the program data is latched into a page buffer. This allows one page of data to be
programmed simultaneously. The programming algorithm for the EEPROM data memory is as
follows (refer to
Data loading):
K: Repeat 3 through 5 until the entire buffer is filled.
L: Program EEPROM page
1. A: Load Command “0001 0001”.
2. G: Load Address High Byte (0x00 - 0xFF).
3. B: Load Address Low Byte (0x00 - 0xFF).
4. C: Load Data (0x00 - 0xFF).
5. E: Latch data (give PAGEL a positive pulse).
1. Set BS2, BS1 to “00”.
2. Give WR a negative pulse. This starts programming of the EEPROM page. RDY/BSY
3. Wait until to RDY/BSY goes high before programming the next page (See
RESET +12V
goes low.
for signal waveforms).
RDY/BSY
PAGEL
XTAL1
DATA
1. “XX” is don’t care. The letters refer to the programming description above.
XA1
XA0
BS1
BS2
WR
OE
0x10
A
“Programming the Flash” on page 373
ADDR. LOW
B
DATA LOW
C
DATA HIGH
D
XX
E
ADDR. LOW
B
Table 29-12 on page
DATA LOW
C
(1)
F
DATA HIGH
D
for details on Command, Address and
XX
E
ADDR. HIGH
G
AT90USB64/128
372. When programming the
ADDR. EXT.H
H
I
XX
Figure 29-4
375

Related parts for AT90USB647-MU