Specifications of AT90USB647-MU

Controller Family/series
AT90
No. Of I/o's
48
Eeprom Memory Size
2KB
Ram Memory Size
4KB
Cpu Speed
16MHz
No. Of
RoHS Compliant
Core Size
8bit
Program Memory Size
64KB
Oscillator Type
External, Internal
Package
64QFN EP
Device Core
AVR
Family Name
AT90
Maximum Speed
20 MHz
Ram Size
4 KB
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
48
Interface Type
SPI/TWI/USART/USB
On-chip Adc
8-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90USB647-MU
Manufacturer:
AAT
Quantity:
18 240
Part Number:
AT90USB647-MUR
Manufacturer:
AD
Quantity:
2 747
12. Timer/Counter0, Timer/Counter1, and Timer/Counter3 Prescalers
12.1
12.2
12.3
98
Internal Clock Source
Prescaler Reset
External Clock Source
AT90USB64/128
Timer/Counter0, 1, and 3 share the same prescaler module, but the Timer/Counters can have
different prescaler settings. The description below applies to all Timer/Counters. Tn is used as a
general name, n = 0, 1 or 3.
The Timer/Counter can be clocked directly by the system clock (by setting the CSn2:0 = 1). This
provides the fastest operation, with a maximum Timer/Counter clock frequency equal to system
clock frequency (f
clock source. The prescaled clock has a frequency of either f
f
The prescaler is free running, i.e., operates independently of the Clock Select logic of the
Timer/Counter, and it is shared by the Timer/Counter Tn. Since the prescaler is not affected by
the Timer/Counter’s clock select, the state of the prescaler will have implications for situations
where a prescaled clock is used. One example of prescaling artifacts occurs when the timer is
enabled and clocked by the prescaler (6 > CSn2:0 > 1). The number of system clock cycles from
when the timer is enabled to the first count occurs can be from 1 to N+1 system clock cycles,
where N equals the prescaler divisor (8, 64, 256, or 1024).
It is possible to use the prescaler reset for synchronizing the Timer/Counter to program execu-
tion. However, care must be taken if the other Timer/Counter that shares the same prescaler
also uses prescaling. A prescaler reset will affect the prescaler period for all Timer/Counters it is
connected to.
An external clock source applied to the Tn pin can be used as Timer/Counter clock (clk
Tn pin is sampled once every system clock cycle by the pin synchronization logic. The synchro-
nized (sampled) signal is then passed through the edge detector.
equivalent block diagram of the Tn synchronization and edge detector logic. The registers are
clocked at the positive edge of the internal system clock (
high period of the internal system clock.
The edge detector generates one clk
= 6) edge it detects.
Figure 1. Tn/T0 Pin Sampling
The synchronization and edge detector logic introduces a delay of 2.5 to 3.5 system clock cycles
from an edge has been applied to the Tn pin to the counter is updated.
Enabling and disabling of the clock input must be done when Tn has been stable for at least one
system clock cycle, otherwise it is a risk that a false Timer/Counter clock pulse is generated.
CLK_I/O
/1024.
Tn
clk
I/O
CLK_I/O
D
LE
Q
). Alternatively, one of four taps from the prescaler can be used as a
Synchronization
D
Q
Tn
pulse for each positive (CSn2:0 = 7) or negative (CSn2:0
clk
D
CLK_I/O
I/O
). The latch is transparent in the
Q
/8, f
Figure 1
CLK_I/O
Edge Detector
shows a functional
/64, f
CLK_I/O
7593K–AVR–11/09
Tn_sync
(To Clock
Select Logic)
Tn
/256, or
). The

Related parts for AT90USB647-MU