AT90USB647-MU Atmel, AT90USB647-MU Datasheet - Page 276

no-image

AT90USB647-MU

Manufacturer Part Number
AT90USB647-MU
Description
MCU, 8BIT, 64K FLASH, USB, 64QFN
Manufacturer
Atmel
Datasheets

Specifications of AT90USB647-MU

Controller Family/series
AT90
No. Of I/o's
48
Eeprom Memory Size
2KB
Ram Memory Size
4KB
Cpu Speed
16MHz
No. Of
RoHS Compliant
Core Size
8bit
Program Memory Size
64KB
Oscillator Type
External, Internal
Package
64QFN EP
Device Core
AVR
Family Name
AT90
Maximum Speed
20 MHz
Ram Size
4 KB
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
48
Interface Type
SPI/TWI/USART/USB
On-chip Adc
8-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90USB647-MU
Manufacturer:
AAT
Quantity:
18 240
Part Number:
AT90USB647-MUR
Manufacturer:
AD
Quantity:
2 747
22.14.1.1
22.15 Isochronous mode
22.15.1
276
AT90USB64/128
Underflow
Abort
If the endpoint uses 2 banks, the second one can be read by the HOST while the current is
being written by the CPU. Then, when the CPU clears FIFOCON, the next bank may be already
ready (free) and TXINI is set immediately.
An “abort” stage can be produced by the host in some situations:
The KILLBK bit is used to kill the last “written” bank. The best way to manage this abort is to per-
form the following operations:
Table 22-1.
An underflow can occur during IN stage if the host attempts to read a bank which is empty. In
this situation, the UNDERFI interrupt is triggered.
An underflow can also occur during OUT stage if the host send a packet while the banks are
already full. Typically, he CPU is not fast enough. The packet is lost.
It is not possible to have underflow error during OUT stage, in the CPU side, since the CPU
should read only if the bank is ready to give data (RXOUTI=1 or RWAL=1)
• after “N” write into UEDATX
• as soon as RWAL is cleared by hardware.
• In a control transaction: ZLP data OUT received during a IN stage,
• In an isochronous IN transaction: ZLP data OUT received on the OUT endpoint during a IN
• ...
stage on the IN endpoint
Abort flow
Abort done
NBUSYBK
UEIENX.
Endpoint
Endpoint
TXINE
Abort
Clear
reset
=0
Yes
No
Yes
KILLBK=1
KILLBK=1
No
Disable the TXINI interrupt.
Abort is based on the fact
that no banks are busy,
meaning that nothing has to
be sent.
Kill the last written
bank.
Wait for the end of the
procedure.
7593K–AVR–11/09

Related parts for AT90USB647-MU