Controller Family/series
AT90
No. Of I/o's
48
Eeprom Memory Size
2KB
Ram Memory Size
4KB
Cpu Speed
16MHz
No. Of
RoHS Compliant
Core Size
8bit
Program Memory Size
64KB
Oscillator Type
External, Internal
Package
64QFN EP
Device Core
AVR
Family Name
AT90
Maximum Speed
20 MHz
Ram Size
4 KB
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
48
Interface Type
SPI/TWI/USART/USB
On-chip Adc
8-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90USB647-MU
Manufacturer:
AAT
Quantity:
18 240
Part Number:
AT90USB647-MUR
Manufacturer:
AD
Quantity:
2 747
7.8.4
7.8.5
7.8.6
7.8.7
56
AT90USB64/128
Internal Voltage Reference
Watchdog Timer
Port Pins
On-chip Debug System
nificantly to the total current consumption. Refer to
on how to configure the Brown-out Detector.
The Internal Voltage Reference will be enabled when needed by the Brown-out Detection, the
Analog Comparator or the ADC. If these modules are disabled as described in the sections
above, the internal voltage reference will be disabled and it will not be consuming power. When
turned on again, the user must allow the reference to start up before the output is used. If the
reference is kept on in sleep mode, the output can be used immediately. Refer to
age Reference” on page 62
If the Watchdog Timer is not needed in the application, the module should be turned off. If the
Watchdog Timer is enabled, it will be enabled in all sleep modes, and hence, always consume
power. In the deeper sleep modes, this will contribute significantly to the total current consump-
tion. Refer to
When entering a sleep mode, all port pins should be configured to use minimum power. The
most important is then to ensure that no pins drive resistive loads. In sleep modes where both
the I/O clock (clk
be disabled. This ensures that no power is consumed by the input logic when not needed. In
some cases, the input logic is needed for detecting wake-up conditions, and it will then be
enabled. Refer to the section
which pins are enabled. If the input buffer is enabled and the input signal is left floating or have
an analog signal level close to V
For analog input pins, the digital input buffer should be disabled at all times. An analog signal
level close to V
input buffers can be disabled by writing to the Digital Input Disable Registers (DIDR1 and
DIDR0). Refer to
able Register 0 – DIDR0” on page 331
If the On-chip debug system is enabled by the OCDEN Fuse and the chip enters sleep mode,
the main clock source is enabled, and hence, always consumes power. In the deeper sleep
modes, this will contribute significantly to the total current consumption.
There are three alternative ways to disable the OCD system:
• Disable the OCDEN Fuse.
• Disable the JTAGEN Fuse.
• Write one to the JTD bit in MCUCR.
“Interrupts” on page 68
CC
I/O
“Digital Input Disable Register 1 – DIDR1” on page 312
/2 on an input pin can cause significant current even in active mode. Digital
) and the ADC clock (clk
for details on the start-up time.
“Digital Input Enable and Sleep Modes” on page 76
CC
/2, the input buffer will use excessive power.
for details on how to configure the Watchdog Timer.
for details.
ADC
) are stopped, the input buffers of the device will
“Brown-out Detection” on page 60
and
“Digital Input Dis-
7593K–AVR–11/09
“Internal Volt-
for details on
for details

Related parts for AT90USB647-MU