EZ80F920120MOD Zilog, EZ80F920120MOD Datasheet - Page 188

MODULE EZ80F92 512K 20MHZ

EZ80F920120MOD

Manufacturer Part Number
EZ80F920120MOD
Description
MODULE EZ80F92 512K 20MHZ
Manufacturer
Zilog

Specifications of EZ80F920120MOD

Module/board Type
Development Module
Processor Series
EZ80F92x
Core
eZ80
Data Bus Width
8 bit
Program Memory Type
Flash
Program Memory Size
1 MB
Interface Type
Cable
Maximum Clock Frequency
20 MHz
Operating Supply Voltage
0 V to 3.3 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Package / Case
LQFP
Development Tools By Supplier
eZ80F920200ZCOG
Minimum Operating Temperature
0 C
For Use With/related Products
eZ80F92
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3157
EZ80F920120MOD
PS015308-0404
Bit
Position
2
ign_low_1
1
ign_low_0
0
single_step
Value Description
0
1
0
1
0
1
P R E L I M I N A R Y
The Ignore the Low Byte function of the ZDI Address
Match 1 registers is disabled. If BRK_ADDR1 is set to 1,
ZDI initiates a BREAK when the entire 24-bit address,
ADDR[23:0], matches the 3-byte value {ZDI_ADDR1_U,
ZDI_ADDR1_H, ZDI_ADDR1_L}.
The Ignore the Low Byte function of the ZDI Address
Match 1 registers is enabled. If BRK_ADDR1 is set to 1,
ZDI initiates a BREAK when only the upper 2 bytes of the
24-bit address, ADDR[23:8], match the 2-byte value
{ZDI_ADDR1_U, ZDI_ADDR1_H}. As a result, a BREAK
can occur anywhere within a 256-byte page.
The Ignore the Low Byte function of the ZDI Address
Match 1 registers is disabled. If BRK_ADDR0 is set to 1,
ZDI initiates a BREAK when the entire 24-bit address,
ADDR[23:0], matches the 3-byte value {ZDI_ADDR0_U,
ZDI_ADDR0_H, ZDI_ADDR0_L}.
The Ignore the Low Byte function of the ZDI Address
Match 1 registers is enabled. If the BRK_ADDR1 is set to
0, ZDI initiates a BREAK when only the upper 2 bytes of
the 24-bit address, ADDR[23:8], match the 2 bytes value
{ZDI_ADDR0_U, ZDI_ADDR0_H}. As a result, a BREAK
can occur anywhere within a 256-byte page.
ZDI SINGLE STEP mode is disabled.
ZDI SINGLE STEP mode is enabled. ZDI asserts a
BREAK following execution of each instruction.
Product Specification
ZiLOG Debug Interface
eZ80F92/eZ80F93
176