XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 203

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
Serial Communications
6-1-2
176
Forced Status 23
Sending data
Receiving
data
Send/receive
Type
No-protocol Communications (RS-232C Port)
Command
23
23
23
23
23
23
FQM1 to Gen-
eral-purpose
external
device
General-pur-
pose external
device to
FQM1
direction
code
Transfer
01
02
05
06
07
0B
11
FORCED SET/RESET
FORCED SET/RESET CANCEL
TRACE PARAMETERS SET
TRACE PARAMETERS READ
TRACE RUN
TRACE DATA READ
DIFFERENTIAL MONITOR RUN
Execute
TXD(236) in
the program
Execute
RXD(235) in
the program
No-protocol Mode is used to send and receive data using the communications
port TXD(236) and RXD(235) I/O instructions in the Coordinator Module lad-
der program, without using retry processing, data conversion, branch pro-
cessing based on received data, or other communications procedures and
without converting the data.
No-protocol mode can be used with the RS-232C and RS-422A ports in the
Coordinator Module. Data can be sent or received in one direction only
between the Module and the general-purpose external device connected to
the RS-232C or RS-422A port.
For example, data can be input from a bar code reader or output to a printer,
or parameter data can be sent and received from a host controller.
The following table lists the no-protocol communications functions available
for the FQM1.
RS-232C port
Method
No protocol
Name
256 bytes
256 bytes
amount of
RS-232C
Max.
data
FQM1
General-purpose external device
Yes: 00 to FF
No: None
Start code
Coordinator Module
Force-sets, force-resets, or clears the forced status
of the specified bits.
Cancels the forced status of all force-set and force-
reset bits.
Sets the trace parameters.
Reads the trace parameter settings.
Executes a trace.
Reads trace data.
Executes differential monitoring.
Frame format
Yes: 00 to FF
CR+LF
None
(Specify recep-
tion data size to
between 1 and
256 bytes when
set to none.)
End code
Coordinator Module ladder program
Function
• Send delay time
• RS and ER signal
Monitoring of CS and
DR signals
(delay between
TXD(236) execution
and sending data
from specified port):
0 to 99,990 ms (unit:
10 ms)
ON/OFF
TXD/RXD
instructions
Other functions
Section 6-1