XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 468

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
Auxiliary Area Allocations
A876
A877
A878
A880
A881
A882
A883
Word
00
01
00
01
07
14
00 to 15 Pulse
00 to 15
00 to 15 Pulse
00 to 15
Bits
Pulse
Output 1
Com-
mand
Bits
Pulse
Output 2
Com-
mand
Bits
Pulse
Output
Control
Bits
(Apply to
both
pulse
outputs 1
and 2.)
Output 1
Monitor
Data
Output 2
Monitor
Data
PV Reset Bit
Range Comparison Results Clear
Bit
PV Reset Bit
Range Comparison Results Clear
Bit
Speed Change Cycle Bit
PLS2 Pulse Output Direction Pri-
ority Mode Bit
Range Comparison Results
Output Bit Pattern
Range Comparison Results
Output Bit Pattern
Name
OFF: Pulse output 1 PV not reset.
ON: Resets pulse output 1 PV.
OFF: Does not clear the execution results (A880) or output bit pat-
tern (A881) from CTBL(882) execution for range comparison for the
pulse output PV.
ON: Clears the execution results (A880) or output bit pattern (A881)
from CTBL(882) execution for range comparison for the pulse output
PV.
Same as for Pulse Output 1 Command Bits.
OFF: Sets the speed change cycle to 2 ms during pulse output to
ACC(888) or PLS2(887).
ON: Sets the speed change cycle to 1 ms during pulse output to
ACC(888) or PLS2(887).
OFF: Sets Direction Priority Mode.
In Direction Priority Mode, pulses are output only when the pulse
output direction and the direction of the specified absolute position
are the same.
ON: Sets Absolute Position Priority Mode.
In Absolute Position Priority Mode, pulses are always output in the
direction of the specified absolute position.
Contains the CTBL(882) execution results for range comparison. Bits
00 to 15 correspond to ranges 1 to 16.
OFF: No match
ON: Match
Contains the output bit pattern when a match is found for CTBL(882)
execution results for range comparison
Note If more than one match is found, an OR of the output bit pat-
terns with matches will be stored here.
Same as for Pulse Output 1 Monitor Data.
Function
Appendix D
441