CX-Programmer: Analog Input/Output Tab Page
Note Analog outputs that are not being used can be disabled to decrease the cycle time.
C-4 Details on System Setup Settings
C-4-1
The input response time can be set for Basic I/O Units by Rack and Slot number. Increasing this value reduces
the effects of chattering and noise. Decreasing this value allows reception of shorter input pulses, (but do not
set the ON response time or OFF response time to less than the cycle time).
The default setting for the input response time is 8 ms and the setting range is 0 to 32 ms. When the input
response time is set to 0 ms, the only delay will be the delays in the Unit’s internal elements (ON delay of 20 s
max., OFF delay of 300 s max.). The input response time settings are transferred to the Basic I/O Units when
the power is turned ON.
404
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
+330 to 331 00 to 15 High-speed
+332 to 333 00 to 15 High-speed
+350
+351
+353
+354
Address
Address
Input such as
a proximity switch
00 to 03 Analog I/O
04 to 07
00 to 07 Analog input
00 to 07 Analog output 1
08 to 11
00 to 07 Analog output 2
08 to 15
Basic I/O Unit Input Response Time
Bits
Bits
Input bit
counter 1 (Counter
1)
counter 2 (Counter
2)
Input response time
Function
Pulses shorter than the
inputresponse time are not received.
Function
Absolute offset
Absolute offset
Input method
Output method
Input range
Output range
Output stop func-
tion
Output range
Output stop func-
tion
Input response time
0 hex: END refresh
0 hex: END refresh (Analog value output to
00 hex: 10 to 10 V
00 hex: 10 to 10 V
Same as for analog output 1.
1 hex: Immediate refresh (using PRV(881)
instruction)
A810 and A811 after executing END(001).)
1 hex: Immediate refresh (using instructions)
(Analog value output when SPED(885) or
ACC(888) is executed.) (A810 and A811 are
used for monitoring.)
01 hex: 0 to 10 V
02 hex: 1 to 5 V (4 to 20 mA)
03 hex: 0 to 5 V
01 hex: 0 to 10 V
02 hex: 1 to 5 V
03 hex: 0 to 5 V
5A hex: Output disabled (Can be used to
shorten I/O refresh time.) (See note.)
0 hex: Clear
1 hex: Hold
2 hex: Maximum value
8000 0000 to 7FFF FFFF hex
Application origin when using an absolute encoder.
Same as high-speed counter 1.
Remarks
Remarks
At power ON
At power ON
At power ON
When setting is read
Appendix C
Immediately
When setting
is read