W83627DHG Nuvoton Technology Corporation of America, W83627DHG Datasheet - Page 51

no-image

W83627DHG

Manufacturer Part Number
W83627DHG
Description
IC I/O CONTROLLER 128-QFP
Manufacturer
Nuvoton Technology Corporation of America
Datasheet

Specifications of W83627DHG

Applications
PC's, PDA's
Interface
LPC
Voltage - Supply
3.3V
Package / Case
128-XFQFN
Mounting Type
Surface Mount
Pin Count
128
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W83627DHG
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
Part Number:
W83627DHG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Company:
Part Number:
W83627DHG
Quantity:
95
Company:
Part Number:
W83627DHG
Quantity:
5 000
Part Number:
W83627DHG-A
Manufacturer:
WINBOND-PBF
Quantity:
3
Part Number:
W83627DHG-A
Manufacturer:
WINBOND/PBF
Quantity:
8
Part Number:
W83627DHG-A
Manufacturer:
WINBOND/PBF
Quantity:
508
Part Number:
W83627DHG-A
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Company:
Part Number:
W83627DHG-A
Quantity:
1 200
Part Number:
W83627DHG-AC
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W83627DHG-C
Manufacturer:
Winbond
Quantity:
1 000
Part Number:
W83627DHG-P
Manufacturer:
Winbond
Quantity:
1 000
Part Number:
W83627DHG-P
Manufacturer:
IDT
Quantity:
165
Part Number:
W83627DHG-P
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W83627DHG-PT
Manufacturer:
NUVOTON
Quantity:
20 000
Part Number:
W83627DHG-PT
0
7.6
This section is divided into two parts, one to measure the speed and one to control the speed.
7.6.1
The W83627DHG can measure fan speed for fans equipped with tachometer outputs. The tachometer
signals should be set to TTL-level, and the maximum input voltage cannot exceed +3.3 V. If the
tachometer signal exceeds +3.3 V, an external trimming circuit should be added to reduce the voltage
accordingly.
The fan speed counter is read from Bank0 Index 28h, 29h, 2Ah, and 3Fh and Bank5 Index 53h. The fan
speed can then be evaluated by the following equation:
The default divisor is 2 and is specified at Bank0 Index 47h, bits 7 ~ 4; Index 4Bh, bits 7 ~ 6; Index 4Ch,
bit 7; Index 59h, bit 7 and bits 3 ~ 2; and Index 5Dh, bits 5 ~ 7. There are three bits for each divisor, and
the corresponding divisor is listed in the table below.
The following table provides some examples of the relationship between divisor, RPM, and count.
BIT 2
2 (default)
DIVISOR
0
0
0
0
Fan Speed Measurement and Control
128
16
32
64
1
4
8
Fan Speed Measurement
BIT 1
0
0
1
1
NOMINAL
8800
4400
2200
1100
RPM
BIT 0
550
275
137
68
0
1
0
1
FAN DIVISOR
REVOLUTION
109.08 ms
218.16 ms
436.32 ms
872.64 ms
TIME PER
13.64 ms
27.27 ms
54.54 ms
6.82 ms
RPM
1
2
4
8
=
Count
1 35 10
-39-
.
COUNTS
BIT 2
×
×
1
1
1
1
Divisor
153
153
153
153
153
153
153
153
6
BIT 1
Publication Release Date: Aug, 22, 2007
0
0
1
1
70% RPM
6160
3080
1540
770
385
192
96
48
BIT 0
0
1
0
1
W83627DHG
FAN DIVISOR
TIME FOR 70%
1246.72 ms
155.84 ms
311.68 ms
623.36 ms
19.48 ms
38.96 ms
77.92 ms
9.84 ms
128
16
32
64
Version 1.4