ATmega169P Automotive Atmel Corporation, ATmega169P Automotive Datasheet - Page 304

no-image

ATmega169P Automotive

Manufacturer Part Number
ATmega169P Automotive
Description
Manufacturer
Atmel Corporation

Specifications of ATmega169P Automotive

Flash (kbytes)
16 Kbytes
Pin Count
64
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
54
Ext Interrupts
17
Usb Speed
No
Usb Interface
No
Spi
2
Twi (i2c)
1
Uart
1
Segment Lcd
100
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
1
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
4
Input Capture Channels
1
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
26.7.11
26.7.12
304
ATmega169P Automotive
Programming the Lock Bits
Reading the Fuse and Lock Bits
Figure 26-5. Programming the FUSES Waveforms
The algorithm for programming the Lock bits is as follows (refer to
page 299
1. A: Load Command “0010 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs the Lock bit. If LB mode 3 is programmed
3. Give WR a negative pulse and wait for RDY/BSY to go high.
The Lock bits can only be cleared by executing Chip Erase.
The algorithm for reading the Fuse and Lock bits is as follows (refer to
on page 299
1. A: Load Command “0000 0100”.
2. Set OE to “0”, BS2 to “0” and BS1 to “0”. The status of the Fuse Low bits can now be
3. Set OE to “0”, BS2 to “1” and BS1 to “1”. The status of the Fuse High bits can now be
4. Set OE to “0”, BS2 to “1”, and BS1 to “0”. The status of the Extended Fuse bits can now
5. Set OE to “0”, BS2 to “0” and BS1 to “1”. The status of the Lock bits can now be read at
6. Set OE to “1”.
(LB1 and LB2 is programmed), it is not possible to program the Boot Lock bits by any
External Programming mode.
read at DATA (“0” means programmed).
read at DATA (“0” means programmed).
be read at DATA (“0” means programmed).
DATA (“0” means programmed).
RESET +12V
RDY/BSY
PAGEL
XTAL1
DATA
for details on Command and Data loading):
XA1
XA0
BS1
BS2
WR
OE
for details on Command loading):
0x40
A
DATA
C
Write Fuse Low byte
XX
0x40
A
DATA
C
Write Fuse high byte
XX
0x40
”Programming the Flash” on
A
”Programming the Flash”
DATA
C
Write Extended Fuse byte
XX
7735B–AVR–12/07

Related parts for ATmega169P Automotive