ATmega169P Automotive Atmel Corporation, ATmega169P Automotive Datasheet - Page 55

no-image

ATmega169P Automotive

Manufacturer Part Number
ATmega169P Automotive
Description
Manufacturer
Atmel Corporation

Specifications of ATmega169P Automotive

Flash (kbytes)
16 Kbytes
Pin Count
64
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
54
Ext Interrupts
17
Usb Speed
No
Usb Interface
No
Spi
2
Twi (i2c)
1
Uart
1
Segment Lcd
100
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
1
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
4
Input Capture Channels
1
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
7735B–AVR–12/07
• Bit 3 – WDE: Watchdog Enable
When the WDE is written to logic one, the Watchdog Timer is enabled, and if the WDE is written
to logic zero, the Watchdog Timer function is disabled. WDE can only be cleared if the WDCE bit
has logic level one. To disable an enabled Watchdog Timer, the following procedure must be
followed:
1. In the same operation, write a logic one to WDCE and WDE. A logic one must be written
2. Within the next four clock cycles, write a logic 0 to WDE. This disables the Watchdog.
In safety level 2, it is not possible to disable the Watchdog Timer, even with the algorithm
described above.
Timer” on page 52.
• Bits 2:0 – WDP2, WDP1, WDP0: Watchdog Timer Prescaler 2, 1, and 0
The WDP2, WDP1, and WDP0 bits determine the Watchdog Timer prescaling when the Watch-
dog Timer is enabled. The different prescaling values and their corresponding Timeout Periods
are shown in
Table 9-3.
Note:
The following code example shows one assembly and one C function for turning off the WDT.
The example assumes that interrupts are controlled (e.g. by disabling interrupts globally) so that
no interrupts will occur during execution of these functions.
WDP2
to WDE even though it is set to one before the disable operation starts.
0
0
0
0
1
1
1
1
Also see
WDP1
Table
0
0
1
1
0
0
1
1
Watchdog Timer Prescale Select
Figure 28-33 on page
See ”Timed Sequences for Changing the Configuration of the Watchdog
9-3.
WDP0
0
1
0
1
0
1
0
1
Oscillator Cycles
Number of WDT
1,024K cycles
2,048K cycles
128K cycles
256K cycles
512K cycles
16K cycles
32K cycles
64K cycles
349.
ATmega169P Automotive
Typical Time-out at
V
CC
15.4 ms
30.8 ms
61.6 ms
0.12 s
0.25 s
0.49 s
1.0 s
2.0 s
= 3.0V
Typical Time-out at
V
CC
14.7 ms
29.3 ms
58.7 ms
0.12 s
0.23 s
0.47 s
0.9 s
1.9 s
= 5.0V
55

Related parts for ATmega169P Automotive