ATUC64L4U Atmel Corporation, ATUC64L4U Datasheet - Page 284

no-image

ATUC64L4U

Manufacturer Part Number
ATUC64L4U
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATUC64L4U

Flash (kbytes)
64 Kbytes
Pin Count
48
Max. Operating Frequency
50 MHz
Cpu
32-bit AVR
# Of Touch Channels
17
Hardware Qtouch Acquisition
Yes
Max I/o Pins
36
Ext Interrupts
36
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
1
Twi (i2c)
2
Uart
4
Lin
4
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
460
Analog Comparators
8
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.62 to 3.6
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
18
Input Capture Channels
12
Pwm Channels
35
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATUC64L4U-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATUC64L4U-AUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATUC64L4U-D3HR
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATUC64L4U-H
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATUC64L4U-U
Manufacturer:
ATMEL
Quantity:
20
Part Number:
ATUC64L4U-ZUT
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
14.6.16
Name:
Access Type:
Reset Value:
• SFV: Store Final Value
• FCD: Fuse Calibration Done
• CTRL: BOD Control
Table 14-5.
• HYST: BOD Hysteresis
• LEVEL: BOD Level
32142A–12/2011
CTRL
SFV
31
23
15
0
1
2
3
7
-
-
-
0: The register is read/write
1: The register is read-only, to protect against further accidental writes.
This bit is cleared after any reset except for a BOD reset, and during flash calibration.
0: The flash calibration will be redone after any reset.
1: The flash calibration will be redone after any reset except for a BOD reset.
This bit is cleared after any reset, except for a BOD reset.
This bit is set when the CTRL, HYST and LEVEL fields have been updated by the flash fuses after a reset.
0: No hysteresis.
1: Hysteresis on.
This field sets the triggering threshold of the BOD. See Electrical Characteristics for actual voltage levels.
Note that any change to the LEVEL field of the BOD register should be done with the BOD deactivated to avoid spurious reset
or interrupt.
BOD Control Register
Operation Mode for BOD
Description
BOD is disabled.
BOD is enabled and can reset the device. An interrupt request will be generated, if enabled in the IMR
register.
BOD is enabled but cannot reset the device. An interrupt request will be generated, if enabled in the IMR
register.
Reserved.
HYST
30
22
14
BOD
Read/Write
-
6
-
-
-
29
21
13
5
-
-
-
28
20
12
4
-
-
-
27
19
11
3
-
-
-
LEVEL
ATUC64/128/256L3/4U
26
18
10
2
-
-
-
25
17
9
1
-
-
CTRL
FCD
24
16
8
0
-
284

Related parts for ATUC64L4U