SAM9RL64 Atmel Corporation, SAM9RL64 Datasheet - Page 418

no-image

SAM9RL64

Manufacturer Part Number
SAM9RL64
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9RL64

Flash (kbytes)
0 Kbytes
Pin Count
217
Max. Operating Frequency
240 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
118
Ext Interrupts
118
Usb Transceiver
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
1
Twi (i2c)
2
Uart
5
Ssc
2
Sd / Emmc
1
Graphic Lcd
Yes
Video Decoder
No
Camera Interface
No
Adc Channels
6
Adc Resolution (bits)
10
Adc Speed (ksps)
220
Resistive Touch Screen
Yes
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
NO
External Bus Interface
1
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.08 to 1.32
Fpu
No
Mpu / Mmu
No / Yes
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
33.9
33.9.1
33.9.2
Figure 33-23. Slave Mode Typical Application Block Diagram
33.9.3
33.9.4
33.9.4.1
418
Slave Mode
AT91SAM9R64/RL64
Definition
Application Block Diagram
Programming Slave Mode
Receiving Data
Read Sequence
Host with
Interface
Master
TWI
The Slave Mode is defined as a mode where the device receives the clock and the address from
another device called the master.
In this mode, the device never initiates and never completes the transmission (START,
REPEATED_START and STOP conditions are always provided by the master).
The following fields must be programmed before entering Slave mode:
As the device receives the clock, values written in TWI_CWGR are not taken into account.
After a Start or Repeated Start condition is detected and if the address sent by the Master
matches with the Slave address programmed in the SADR (Slave ADdress) field, SVACC (Slave
ACCess) flag is set and SVREAD (Slave READ) indicates the direction of the transfer.
SVACC remains high until a STOP condition or a repeated START is detected. When such a
condition is detected, EOSACC (End Of Slave ACCess) flag is set.
In the case of a Read sequence (SVREAD is high), TWI transfers data written in the TWI_THR
(TWI Transmit Holding Register) until a STOP condition or a REPEATED_START + an address
different from SADR is detected. Note that at the end of the read sequence TXCOMP (Transmis-
sion Complete) flag is set and SVACC reset.
As soon as data is written in the TWI_THR, TXRDY (Transmit Holding Register Ready) flag is
reset, and it is set when the shift register is empty and the sent data acknowledged or not. If the
data is not acknowledged, the NACK flag is set.
TWD
TWCK
1. SADR (TWI_SMR): The slave device address is used in order to be accessed by mas-
2. MSDIS (TWI_CR): Disable the master mode.
3. SVEN (TWI_CR): Enable the slave mode.
ter devices in read or write mode.
Host with TWI
Interface
Slave 1
Host with TWI
Interface
Slave 2
LCD Controller
Slave 3
R
R
VDD