EP9315-CBZ Cirrus Logic Inc, EP9315-CBZ Datasheet - Page 619

IC ARM9 SOC ENH UNIV 352PBGA

EP9315-CBZ

Manufacturer Part Number
EP9315-CBZ
Description
IC ARM9 SOC ENH UNIV 352PBGA
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9315-CBZ

Core Size
16/32-Bit
Core Processor
ARM9
Speed
200MHz
Connectivity
EBI/EMI, EIDE, Ethernet, I²C, IrDA, Keypad/Touchscreen, PCMCIA, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LCD, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
16
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 8x12b
Oscillator Type
External
Operating Temperature
0°C ~ 70°C
Package / Case
352-BGA
Controller Family/series
(ARM9)
No. Of I/o's
16
Cpu Speed
200MHz
No. Of Timers
5
Digital Ic Case Style
BGA
Supply Voltage Range
1.65V To 1.94V, 3V To 3.6V
Embedded Interface Type
SPI
Rohs Compliant
Yes
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
EDB9315A-Z
Case
BGA
Dc
06+
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1144 - KIT DEVELOPMENT EP9315 ARM9
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
 Details
Other names
598-1139

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9315-CBZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
EP9315-CBZ
Manufacturer:
ALTERA
0
Part Number:
EP9315-CBZ
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
EP9315-CBZ
Quantity:
48
Register Descriptions
IrEnable
DS785UM1
17.6 Registers
31
15
Address:
Default:
Definition:
Bit Descriptions:
30
14
29
13
28
12
0x808B_0000 - Read/Write
0x0000_0018
IrDA Enable Register. This register selects which Infrared interface module is
active. The Medium and Fast modules share common control, flag, and data
interfaces while maintaining separate status registers.
RSVD:
FD:
MD:
LBM:
27
11
RSVD
26
10
Copyright 2007 Cirrus Logic
25
9
Reserved. Unknown During Read.
Fast done status. Read-only bit indicating that the FIR
transmit module has completed transition of the current
frame and that it is safe to disable the module using the
EN control bits.
Medium done status. Read-only bit indicating that the MIR
transmit module has completed transmission of the current
frame and that it is safe to disable the module using the
EN control bits.
Loopback Mode, for MIR and FIR operation.
0 - Normal operation.
1 - Loopback active, the transmit serial shifter is directly
connected to the receive serial shifter.
24
8
RSVD
23
7
22
6
21
5
FD
20
4
MD
19
3
EP93xx User’s Guide
LBM
18
2
17
1
EN
17-23
IrDA
16
0
17

Related parts for EP9315-CBZ