R4F24268NVFQV Renesas Electronics America, R4F24268NVFQV Datasheet - Page 1040

MCU 256K FLASH 48K 144-LQFP

R4F24268NVFQV

Manufacturer Part Number
R4F24268NVFQV
Description
MCU 256K FLASH 48K 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2400r
Datasheet

Specifications of R4F24268NVFQV

Core Processor
H8S/2600
Core Size
16/32-Bit
Speed
33MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, SSU, UART/USART
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
48K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R4F24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
R4F24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 17 A/D Converter
17.4.2
In scan mode, A/D conversion is to be performed sequentially on the analog inputs of the specified
channels up to four or eight* channels. Two types of scan mode are provided, that is, continuous
scan mode where A/D conversion is repeatedly performed and one-cycle scan mode where A/D
conversion is performed for the specified channels for one cycle.
(1)
1. When the ADST bit in ADCSR is set to 1 by software, TPU, TMR, or an external trigger
2. When A/D conversion for each channel is completed, the A/D conversion result is sequentially
3. When A/D conversion of all selected channels is completed, the ADF bit in ADCSR is set to 1.
4. The ADST bit is not cleared automatically, and steps 2 to 3 are repeated as long as the ADST
Note: * Only possible in the H8S/2426 group and H8S/2426R group.
Page 1010 of 1372
input, A/D conversion starts on the first channel in the specified channel group. Consecutive
A/D conversion on a maximum of four channels (SCANE and SCANS = B'10) or on a
maximum of eight channels (SCANE and SCANS = B'11) can be selected. When consecutive
A/D conversion is performed on four channels, A/D conversion starts on AN0 when CH3 and
CH2 of unit 0 = B'00, on AN4 when CH3 and CH2 of unit 1 = B'01, on AN8* when CH3 and
CH2 of unit 1 = B'10, or on AN12 when CH3 and CH2 of unit 1= B'11. When consecutive
A/D conversion is performed on eight channels, A/D conversion starts on AN0 when CH3 =
B'0 or on AN8* when CH3 = B'1.
transferred to the corresponding ADDR of each channel.
If the ADIE bit is set to 1 at this time, an ADI interrupt request is generated. A/D conversion of
the first channel in the group starts again.
bit remains set to 1. When the ADST bit is cleared to 0, A/D conversion stops and the A/D
converter enters wait state. If the ADST bit is later set to 1, A/D conversion starts again from
the first channel in the group.
Continuous Scan Mode
Scan Mode
H8S/2426, H8S/2426R, H8S/2424 Group
REJ09B0466-0350 Rev. 3.50
Jul 09, 2010