R4F24268NVFQV Renesas Electronics America, R4F24268NVFQV Datasheet - Page 536

MCU 256K FLASH 48K 144-LQFP

R4F24268NVFQV

Manufacturer Part Number
R4F24268NVFQV
Description
MCU 256K FLASH 48K 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2400r
Datasheet

Specifications of R4F24268NVFQV

Core Processor
H8S/2600
Core Size
16/32-Bit
Speed
33MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, SSU, UART/USART
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
48K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R4F24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
R4F24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 9 Data Transfer Controller (DTC)
9.8
9.8.1
DTC operation can be disabled or enabled using the module stop control register. The initial
setting is for DTC operation to be enabled. Register access is disabled by setting the module stop
state. The module stop state cannot be set while the DTC is activated. For details, refer to section
23, Power-Down Modes.
9.8.2
The MRA, MRB, SAR, DAR, CRA, and CRB registers are all located in on-chip RAM. When the
DTC is used, the RAME bit in SYSCR must not be cleared to 0 and the corresponding MSTP bit
in RMMSTPCR must not be set to 1.
9.8.3
For DTCE bit setting, use bit manipulation instructions such as BSET and BCLR. If all interrupts
are disabled, multiple activation sources can be set at one time (only at the initial setting) by
writing data after executing a dummy read on the relevant register.
9.8.4
When DTC transfer is activated by a DMAC transfer end interrupt, regardless of the transfer
counter and DISEL bit, the DMAC's DTE bit is not subject to DTC control, and the write data has
priority. Consequently, an interrupt request may not be sent to the CPU when the DTC transfer
counter reaches 0.
9.8.5
When chain transfer is used, clearing of the activation source or DTCER is performed when the
last of the chain of data transfers is executed. SCI and high-speed A/D converter
interrupt/activation sources, on the other hand, are cleared when the DTC reads or writes to the
prescribed register. Therefore, when the DTC is activated by an interrupt or activation source, if a
read/write of the relevant register is not included in the last chained data transfer, the interrupt or
activation source will be retained.
Page 506 of 1372
Usage Notes
Module Stop Function Setting
On-Chip RAM
DTCE Bit Setting
DMAC Transfer End Interrupt
Chain Transfer
H8S/2426, H8S/2426R, H8S/2424 Group
REJ09B0466-0350 Rev. 3.50
Jul 09, 2010