Specifications of MPC564CZP40

Core Processor
PowerPC
Core Size
32-Bit
Speed
40MHz
Connectivity
CAN, EBI/EMI, SCI, SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
56
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
2.5 V ~ 2.7 V
Data Converters
A/D 32x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
388-BGA
Processor Series
MPC5xx
Core
PowerPC
Data Bus Width
32 bit
Data Ram Size
32 KB
Interface Type
CAN, JTAG, QSPI, SCI, SPI, UART
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
56
Number Of Timers
2
Operating Supply Voltage
0 V to 5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
2 (10 bit, 32 Channel)
For Use With
MPC564EVB - KIT EVAL FOR MPC561/562/563/564
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC564CZP40
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
24.10 Read/Write Access
The read/write access feature allows access to internal memory-mapped space via the auxiliary port.
Read/write mechanism supports single and block, reads and writes.
24.10.1 Functional Description
The READI module is capable of bus mastership on the L-bus and for setting up and reading data and
status.
All accesses are setup and initiated to the read/write access register (RWA) and upload/download
information register (UDI) via the four auxiliary access public messages: device ready for
upload/download, upload request (tool requests information), download request (tool provides
information), upload/download information (device/tool provides information).
Read/write access features are enabled by setting the appropriate fields in the RWA register. For details on
field configuration, refer to
The functional flow for read/write access to memory-mapped locations and MPC500 registers is depicted
in
Freescale Semiconductor
Figure
TCODE = 8
Error Code = 0b00111 (Program/Data/Ownership trace overrun)
MCKO
MSEO
MDO[7:0]
24-59.
Figure 24-54. Error Message (Program/Data/Ownership Trace Overrun)
TCODE (17)
[6 bits]
Section 24.6.1.7, “Read/Write Access Register
MPC561/MPC563 Reference Manual, Rev. 1.2
Figure 24-56. Read Register Message
Figure 24-55. Target Ready Message
Max Length = 14 bits
Min Length = 14 bits
Max Length = 6 bits
Min Length = 6 bits
TCODE (16)
11001000
[6 bits]
Opcode
[8 bits]
00000001
Don’t care data
(idle clock)
(RWA).”
00000000
READI Module
24-59