CQM1-CIF01 Omron, CQM1-CIF01 Datasheet - Page 105

no-image

CQM1-CIF01

Manufacturer Part Number
CQM1-CIF01
Description
PERIPHERAL CABLE FOR NEC COMP.
Manufacturer
Omron
Datasheet

Specifications of CQM1-CIF01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
84
7-3
7-4
Operating Memory Area Monitoring
Operating Memory Area Monitoring
Operating Data Area Monitoring
1,2,3...
1,2,3...
Use the following procedure to monitor the operating memory area (Special I/
O Unit words allocated in the CIO Area) allocated to the PLC.
1. On the project tree, select the Position Control Unit for operating memory
2. Select Online - Online Monitor NC Operating Memory Area.
3. Select either Automatic or Manual to start monitoring. Automatic continues
Use the following procedure to monitor the operating data area (Special I/O
Unit words allocated in the DM Area or custom DM/EM Area) allocated to the
PLC.
1. On the project tree, select the Position Control Unit for operating data area
2. Select Online - Online Monitor NC Operating Data Area.
area monitoring.
monitoring until the Stop Monitor Button is clicked. Manual refreshes the
monitor window contents.
The following table shows the operating memory area words that are dis-
played.
Refer to the CX-Position Online Help or the Operation Manual for the Po-
sition Control Unit for details on bit allocations.
monitoring.
Command 1
Command 2
NC status
External I/O
status
Error codes
Data
n
n+1
n+2
n+3
n+4
NC1@3
X axis
n
n+1
n+4
n+5
n+6
X axis
NC2@3
n+2
n+3
n+7
n+8
n+9
Y axis
Allocated words
n
n+1
n+8
n+9
n+10
X axis
n+11
n+2
n+3
n+12
n+13
Y axis
NC4@3
n+4
n+5
n+14
n+15
n+16
Z axis
Section 7-3
n+6
n+7
n+17
n+18
n+19
U axis

Related parts for CQM1-CIF01