74
Setting and Changing Communications Specifications
For local network com-
munications, set 0.
Use the default setting
normally. When commu-
nications are estab-
lished through 2 or more
types of networks, use
the shorter frame length.
1,2,3...
1. Select the Project Icon in the project workspace, and click
2. Click the Settings Button on the right of the Network Type Selection Box.
3. Click the Driver Tab. Set the contents shown below. Setting the port to
bar or select Edit - New PC. The Add PLC Dialog Box will be displayed.
Set the device name, device type, and network type as shown below.
The content of the Network Tab Page in the Network Settings [Toolbus] Di-
alog Box will be displayed. Set them as shown below.
PLC100 is not necessary here. Set the same baud rate for between the
CX-Position and PC000. When using a CS-series CPU Unit, and selecting
the Baud Rate Auto-Detect option, communications will be established
with the baud rate set here regardless of the communications settings on
the CPU Unit. In this example, communications port 1 on the personal
computer is connected to the RS-232C port on PLC000 with a cable, and
pin 5 on the DIP switch on the CPU Unit is set to ON.
Set 1 for node address.
If timeouts occur, set a
longer response time-
out time.
Section 6-2
in the tool-